Inspection
Inspection Details
Equipment ID
6986
6986
Inspection Date
10/9/2024
10/9/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Phillip Moise, Jr.
Phillip Moise, Jr.
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
20
20
External ID
78121c2c-96a8-47a1-b8f3-a19ff2027708
78121c2c-96a8-47a1-b8f3-a19ff2027708
Location
Tower Grove Manor
2710 S Grand Blvd, St. Louis, MO
Phone: (314) 773-2800
2710 S Grand Blvd, St. Louis, MO
Phone: (314) 773-2800
Owner
Attn: Tine Kaufmann
Tower Grove Manor
2710 S Grand Blvd, St. Louis, MO 63118
Phone: (314) 773-2800
Alt Phone: (314) 678-3000
Email: tkaufmann@standrews1.com
Tower Grove Manor
2710 S Grand Blvd, St. Louis, MO 63118
Phone: (314) 773-2800
Alt Phone: (314) 678-3000
Email: tkaufmann@standrews1.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in car emergency lighting shall be operational. | 9/15/2020 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | x | The in car emergency lighting shall be operational. - Facilities and mechanic were unable to located 110v disconnect to test emergency lighting. | 10/6/2020 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO state operating certificate shall be displayed in the elevator machine room. | |||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | x | Car door restrictor shall be operational. | 10/11/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.4 Access to Pit | The pit access door shall be self-closing. | 10/11/2022 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | x | Pit access door shall have a electric contact conforming to 2.26.2.26 to prevent operation of the elevator when the pit door is open. | 10/11/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | The pit shall be kept clean. | |||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean and dry. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door shall be self-closing and self-locking. | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Door restrictor is missing the arm and shall be repaired. | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Machine room shall be kept clean and free from non-elevator materials. | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. |