Inspection
Inspection Details
Equipment ID
9119
9119
Inspection Date
10/9/2024
10/9/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Phillip Moise, Jr.
Phillip Moise, Jr.
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
30
30
External ID
e15e1ced-0bfb-45fe-93f9-47e5d1c766f5
e15e1ced-0bfb-45fe-93f9-47e5d1c766f5
Location
Comfort Inn Westport
12031 Lackland Rd, St. Louis, MO
Phone: (314) 853-0576
12031 Lackland Rd, St. Louis, MO
Phone: (314) 853-0576
Owner
Attn: Comfort Inn Westport
Comfort Inn Westport
12031 Lackland Rd, St. Louis, MO 63146
Phone: (000) 000-0000
Email: greeley@bridgeton.com
Comfort Inn Westport
12031 Lackland Rd, St. Louis, MO 63146
Phone: (000) 000-0000
Email: greeley@bridgeton.com
Billing
Attn: Comfort Inn Westport
Comfort Inn Westport
12031 Lackland Rd, St. Louis, MO 63146
Phone: (000) 000-0000
Email: paresh@comfortinnstl.com
Comfort Inn Westport
12031 Lackland Rd, St. Louis, MO 63146
Phone: (000) 000-0000
Email: paresh@comfortinnstl.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | x | Clean the elevator pit. | 6/18/2019 | |
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | 8.6.1.4.1 - Provide code compliant maintenance records. | 6/1/2020 | ||
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide come compliant maintenance records. | 6/1/2020 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit shall be kept clean. | 6/1/2020 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO state operating certificate shall be posted in the elevator machine room. | 6/1/2020 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/14/2023 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | Pit light switch shall be accessible from pit access door. | 9/13/2023 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Pit ladder shall extend not less than 30" above sill of access door. | 9/13/2023 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Up-to-date operating certificate is required in the machine room. | 9/13/2023 | ||
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit light switch shall be accessible from the pit access door. | |||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. The lock hardware is missing and the door cannot lock. | |||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | The auxiliary power lowering operating shall be functional. | 10/9/2024 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | A written record shall be kept of the quantity of hydraulic fluid added to the system and emptied from leakage collection containers and pans, shall not exceed 5 gal before removal, shall be covered, and shall not be permitted to overflow. Note: Per the State of Missouri AHJ: "The use of oil recovery systems to return the hydraulic fluid back into the main reservoir by automatic means or by gravity feed prevents proper monitoring of the gland packing and seals", and "machine rooms cannot be used as containment areas.” | |||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | A category 5 test is due on the overspeed valve in 2025. | |||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit light switch shall be accessible from the pit access door. |