Inspection
Inspection Details
Equipment ID
8900
8900
Inspection Date
10/9/2024
10/9/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Matthew Martin
Matthew Martin
Relief Valve Pressure
370
370
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
19
19
External ID
61bf91c9-0fcf-4b01-8c1f-1c41ed0239d3
61bf91c9-0fcf-4b01-8c1f-1c41ed0239d3
Location
Extended Stay America Suites St. Louis Fenton
1662 Fenton Business Park Ct, Fenton, MO
Phone: (636) 305-7000
1662 Fenton Business Park Ct, Fenton, MO
Phone: (636) 305-7000
Owner
Attn: Licensing
Extended Stay America Suites St. Louis Fenton
5301 Headquarters Dr, Plano, TX 75024
Phone: (972) 952-0200
Email: licensing@aimhosp.com
Extended Stay America Suites St. Louis Fenton
5301 Headquarters Dr, Plano, TX 75024
Phone: (972) 952-0200
Email: licensing@aimhosp.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 10/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | The car door light ray shall be operational. | 10/28/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be obtained and displayed in the elevator machine room. | 10/16/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | Electric photo eye re-opening device shall be operable. Re-Inspection Required (2nd Notice) | 3/7/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/5/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 11/30/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Access to the machine space shall maintained in a clear and unobstructed manner. There is debris on the floor of the room leading to the machine room and blocking access to it - including broken fluorescent bulbs. | 11/30/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. The machine room door is being blocked from closing due to an excessive amount of debris on the floor of the room leading to it. | 11/30/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | An ABC fire extinguisher with a current test tag shall be mounted convenient to the machine room door. | 11/30/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall be operational. | 11/30/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lights shall be operational. | 11/30/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A current tested & tagged ABC type fire extinguisher shall be provided in the elevator machine room. |