Inspection
Inspection Details
Equipment ID
12891
12891
Inspection Date
11/1/2024
11/1/2024
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Vernon Livergood
Vernon Livergood
Mechanic Name
Jasen Kennedy
Jasen Kennedy
Relief Valve Pressure
Slide
8
8
Governor Rope Pull
00
00
Door Closing Force
18
18
External ID
f913ffea-f87c-43cb-9ce8-2247d866a0e3
f913ffea-f87c-43cb-9ce8-2247d866a0e3
Location
Independence Tower Apartments
728 N Jennings Rd, Independence, MO
Phone: (816) 257-1400
728 N Jennings Rd, Independence, MO
Phone: (816) 257-1400
Owner
Attn: Independence Tower Apartments
Independence Tower Apartments
728 N Jennings Rd, Independence, MO 64056
Phone: (000) 000-0000
Email: wdaniel@tarantino.com
Independence Tower Apartments
728 N Jennings Rd, Independence, MO 64056
Phone: (000) 000-0000
Email: wdaniel@tarantino.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Emg. phone not working | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | runby less than 2 ins. need to shorten cables | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Car top oily an dirty an shall not be used for storage | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Water an oil shall not be allowed to accumulate on pit floor pit has a lot of trash in it. | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | No data tags on Hoist ropes | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Car door restrictor not working. | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Missing fire hat covers in car an at hall sta. | 8/20/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | No gov. rope tags | 8/20/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.15 - sign and operating device symbols | 8.11.2.1.1(o) | No | No | fire hat jewell missing | 11/18/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 2.4.2 | Yes | No | runby less than 6 ins cant reach final limit need to shorten ropes | 9/7/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | pit has standing water an trash | 11/18/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 2.20.2 | No | No | no rope data tage | 11/18/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Provide working 2 way communication | 9/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | Yes | No | Shorten ropes to allow unit to activate final | 9/7/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | No | No | Provide capacity plate for car | 9/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Provide emergency light and bell | 9/7/2022 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | No | No | Provide rope data tag | 9/7/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Provide rope data tags. | 11/1/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | REMOVE TRASH AND DEBRIS FROM PIT | 11/1/2024 |