Inspection
Inspection Details
Equipment ID
13632
13632
Inspection Date
11/8/2024
11/8/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Thomas Suedkamp
Thomas Suedkamp
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
23
23
External ID
53842b1a-63c9-428d-969c-7704fc407d5d
53842b1a-63c9-428d-969c-7704fc407d5d
Location
Fairmont Apartments
7 Maryland Plz, St. Louis, MO
Phone: (314) 280-6933
7 Maryland Plz, St. Louis, MO
Phone: (314) 280-6933
Owner
Attn: Fairmont Apartments
Fairmont Apartments
7 Maryland Plz, St. Louis, MO 63108
Phone: (314) 454-3515
Email: mgrsenior@kohner.com
Fairmont Apartments
7 Maryland Plz, St. Louis, MO 63108
Phone: (314) 454-3515
Email: mgrsenior@kohner.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.3 - Operating control devices | 2.26.1.1 | Yes | No | Fasten COP cover. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.12 - Car enclosure | 2.14 | Yes | No | Secure ceiling panels. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.14 - Code data plate | 8.9 | Yes | No | Put correct information on controller data tag. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.19 - Car Ride | 8.11.2.1.1(s) | Yes | No | Correct source of grinding noise. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.7 - Car leveling and anticreep devices | 8.11.2.1.3(j) | Yes | No | Car must stop level with the floor. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.8 - Top emergency exit | 8.11.2.1.3(l) | Yes | No | Properly secure emergency exit. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 8.11.2.1.3(p) | Yes | No | Cover large hole at top of hoistway. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | Yes | No | Install electrical box covers on top of car. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | Yes | No | Provide crosshead data tag. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | Yes | No | Provide code compliant pit lighting. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | Yes | No | Pit shall be cleaned. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 8.11.2.1.5(j) | Yes | Yes | Safety plank is riding on guide rails. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 8.10.2.2.5(c) | Yes | No | Install a counterweight guard in the pit. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | Yes | Yes | Test all phases of fire service and all initiating devices. | 8/2/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.14 - Code data plate | 8.9 | No | No | The code data plate information is not is not correct. The code data plate shall list all the items that were altered and the correct code reference. | 8/29/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.28 - Counterweight and counterweight buffer | 8.11.2.1.3(m) | No | No | The counterweight is missing the cotter pins to retain the counterweight at the bottom. | 8/29/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | Yes | Yes | The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: In phase I operation, the car doors do not close automatically when they are in the open position. Stop operation order issued, reinspection required. | 8/29/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.14 - Code data plate | 8.7.1.8 | No | No | The code data plate information is not is not correct. The code data plate shall list all the items that were altered and the correct code reference. | 10/15/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.28 - Counterweight and counterweight buffer | 8.11.2.1.3(m) | No | No | The counterweight is missing the cotter pins to retain the counterweight at the bottom. | 10/15/2019 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Provide updated MCP | 12/14/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove water from pit. Provide means to prevent accumulation of standing water | 12/14/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Observed mold in pit. Repair as needed | 12/14/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)6 | No | No | Controller has incorrect car number, repair as needed | 12/14/2021 |
| A17.1-1996 : Elevators | 3.9 - Floor and emergency identification numbering | 1001.2(c)(15) | No | No | Number car top | 12/14/2021 |
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 1001.2(c)(2) | No | No | Provide car top light to work | 12/14/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Light in elevator pit is not working, needs repair. Re-inspection required | 10/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 2.29.1 | No | No | COP has incorrect car number, repair as needed. | 10/25/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 2.29.1 | No | No | Top of car has incorrect car number. | 10/25/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Unable to communicate with emergency personnel over phone. Re-inspection required | 1/15/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Yes | No | Repair or replace T cable. Near floor the T cable is heavily gouged showing through to the copper wiring. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.11 Runby (Re-Inspection) | Yes | No | Hoist ropes shall be shortened to increase runby measurement. |