Inspection
Inspection Details
Equipment ID
25795
25795
Inspection Date
10/17/2024
10/17/2024
Inspection Type
New Installation
New Installation
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Bobby Strader
Bobby Strader
Relief Valve Pressure
NA
NA
Slide
18"
18"
Governor Rope Pull
17/200
17/200
Door Closing Force
18
18
External ID
5d5d1b7a-9731-4084-8eb1-2e3f52ebb012
5d5d1b7a-9731-4084-8eb1-2e3f52ebb012
Location
3681 Lindell
3681 Lindell Blvd, St. Louis, MO
Phone: (314) 540-5988
Email: bhayden@stlluxury.com
3681 Lindell Blvd, St. Louis, MO
Phone: (314) 540-5988
Email: bhayden@stlluxury.com
Owner
Attn: Bryan Hayden
St. Louis Luxury
3681 Lindell Blvd, St. Louis, MO 63108
Phone: (314) 540-5988
Email: bhayden@stlluxury.com
St. Louis Luxury
3681 Lindell Blvd, St. Louis, MO 63108
Phone: (314) 540-5988
Email: bhayden@stlluxury.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | Yes | No | Secure metallic wiring properly in top of hoistway. | 1/30/2025 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | Yes | No | Top of hoistway lighting switch must be accessible & visible from both landings. | 1/30/2025 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | Yes | No | GFI located in top of hoistway shall work. | 1/30/2025 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.7.9.1 | Yes | No | Machine space lighting shall be not less than 19fc with cartop level on top floor, as measured from the cartop. | 1/30/2025 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Orange spray foam "Fire Block" not allowed. Product is not compliant with IBC or NFPA 72 as 1.5hr fire rated fire penetration sealant for commercial applications. Hoistway penetration sealant must be a compliant fire resistive sealant product. Replace/recover with compliant product. Non-compliance statement can be found on the back of the cans of the existing orange sealant. | 1/30/2025 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Yellow spray foam insulation not allowed. Product is not compliant with IBC or NFPA 72 as a 1.5hr fire rated fire penetration sealant for commercial applications. Hoistway wall covering must be a compliant fire restrictive product. Replace/recover with compliant product or provide compliance rating documentation for current sealant. Contractor indicated they may apply DC315 Coating at a minimum wet film thickness of 24mil wet (based on ICC ESR-3500 for Proseal LE) will create the thermal barrier needed and maintain the integrity of the insulation in the event of a hoistway fire. | 1/30/2025 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | There is exposed wood, without fire-rated coating, throughout the hoistway, under sill, etc. | 1/30/2025 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump Pump Required/Capacity (Re-Inspect) | Yes | No | Provided pit sump pump documentation to ensure proper capacity (3000 GPH per elevator at 14' of head) and the presence of automatic float operation (no float switch seen at this time). | 1/30/2025 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.7.9.1 | Yes | No | Lighting at controller access floor (10th floor) shall not be less than 19fc, measured at the floor level. | 1/30/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Yes | No | Mainline and lighting disconnects need feeder location labeling. | 1/30/2025 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Yes | No | 10th floor fire extinguisher shall be ABC rated, not just BC rated. | 1/30/2025 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2 Phase I Operation Recall by Initiating Device | Yes | Yes | FAID failed to initiate elevator recall. Test all devices. | 1/30/2025 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.1.1 Phase I Emergency Recall Operation | Yes | Yes | Lobby fire status panel display damaged. Repair and fully test. | 1/30/2025 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8 | Yes | No | Fire suppression/sprinkler systems in elevator lobbies not fully installed at this time. Verification of completed installation required. | 1/30/2025 |