Inspection
Inspection Details
Equipment ID
13946
13946
Inspection Date
11/8/2024
11/8/2024
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
28
28
External ID
cc831129-3a05-4883-9f95-1884a23e2398
cc831129-3a05-4883-9f95-1884a23e2398
Location
U-Haul Center of Kingshighway
1641 S Kingshighway Blvd, St. Louis, MO
Phone: (314) 773-1400
1641 S Kingshighway Blvd, St. Louis, MO
Phone: (314) 773-1400
Owner
Attn: U-Haul International
U-Haul International
PO Box 21502, Phoenix, AZ 85036
Phone: (000) 000-0000
U-Haul International
PO Box 21502, Phoenix, AZ 85036
Phone: (000) 000-0000
Billing
Attn: U-Haul Company of St. Louis
U-Haul Company of St. Louis
418 S Tucker Blvd, St. Louis, MO 63102
Phone: (314) 766-4009
Email: Erica_Norman@uhaul.com
U-Haul Company of St. Louis
418 S Tucker Blvd, St. Louis, MO 63102
Phone: (314) 766-4009
Email: Erica_Norman@uhaul.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Still need to test counterweight buffer. | 8/23/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Still need to test fire service. | 8/23/2018 |
| conversion | conversion | n/a | No | No | Recommend fall protection railing on top of car. | 10/1/2019 |
| conversion | conversion | n/a | No | No | Car top light shall work and shall be guarded. | 10/1/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Phase 2 fire service does not work. | 8/23/2018 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Phase 2 fire service does not work. | 8/23/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A code compliant maintenance control program (MCP) shall be available and the documentation required to be kept on site, shall be located in the machine room. | 10/7/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | The smoke detectors in the elevator lobbies shall be connected to the elevators and tested for proper operation. Unit left in service and local fire department notified of the situation. Violation corrected 9/28/2020 and scheduled for re-inspection on 10/9/2020. | 10/9/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 11/3/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 11/3/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide a code compliant MCP including onsite documents. No maintenance charts. No Monthly Fire service checklist. No repair or test logs. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | No | No | Need to post capacity inside the elevator cab | |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Need to replace all open wiring on car top with NFPA 70 code compliant wiring. Re-inspection required |