Inspection
Inspection Details
Equipment ID
23196
23196
Inspection Date
12/11/2024
12/11/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Richard Hawkins
Richard Hawkins
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
e232202c-f663-4e58-ab35-1394e9fedc9f
e232202c-f663-4e58-ab35-1394e9fedc9f
Location
United Bags, Inc
2508 N Broadway, St. Louis, MO
Phone: (000) 000-0000
2508 N Broadway, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: United Bags, Inc
United Bags, Inc
1355 N Warson Rd, St. Louis, MO 63132
Phone: (000) 000-0000
United Bags, Inc
1355 N Warson Rd, St. Louis, MO 63132
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher in machine room is due to be serviced or replaced. | 11/21/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Lighting in the machine room shall be not less than ten (10) foot-candles at floor level. | 11/21/2025 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)6 | No | No | Each Freight Enclosure shall have a “No Passengers” sign conspicuously posted. Letters shall not be less than one-half inch (1/2") high. | 11/21/2025 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | No | No | The space between the solid section and the car top shall be covered solid or with perforated or lattice-type work. The perforated or lattice work shall reject ball one and one-half inches (1 1/2") in diameter | 11/21/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)7 | Yes | Yes | An enclosed stop switch meeting the requirements of ASME A17.1, 1995 edition, rule 210.2(e) shall be installed in the pit of all power elevators and be accessible from the pit access door. | 9/6/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | A permanent lighting fixture shall be provided in all pits to provide an illumination of not less than five (5) foot candles at the pit floor. The fixture switch shall be provided and accessible from the pit access door. | 11/21/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)3 | No | No | All elevators shall have counterweight guards. Guards shall be of unperforated metal of at least the strength of or braced to the equivalent strength of number fourteen (14) gauge sheet steel. Guards shall extend from a point not more than twelve inches (12") above the pit floor to a point not less than seven feet (7') above the pit floor. Where guards are not feasible, warning chains shall be installed on the bottom of the counter weights and shall extend no less than five feet (5') below counterweight. Chains shall be of a number ten (10) U.S. gauge wire or of equal size. Exception: When compensating chains or ropes are used, a counterweight guard is not required. | 11/21/2025 |
| MO Minimum : Elevators | (A) - Hoistways | (A)4 | Yes | Yes | The bottom floor hoistway doors or gates shall withstand a force of two hundred fifty (250) pounds pressure applied in the center of the gate without breaking or forcing it out of its guides. | 9/6/2024 |
| MO Minimum : Elevators | (A) - Hoistways | (A)6 | Yes | Yes | The bottom floor hoistway door or gate shall be provided with interlocks designed to prevent the car from moving unless the doors or gates are closed. Where doors or gates do not lock when closed they shall lock when the elevator is not more than twelve inches (12") away from the floor. Passenger elevator hoistway doors shall be closed and locked before the car leaves the floor. | 9/6/2024 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | Yes | Yes | A fused disconnect means for all elevators shall be provided. Disconnect switch shall be located in the machine room and be readily accessible from the machine. | 9/6/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | Yes | Governor rope is damaged and needs to be replaced. | 9/6/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Inspection incomplete. Need to do safeties pullout/PullThru and set the safeties with a full load. | 9/6/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Lighting in the machine room shall be not less than ten (10) foot-candles at floor level. | 11/21/2025 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | Yes | No | The space between the solid section and the car top shall be covered solid or with perforated or lattice-type work. The perforated or lattice work shall reject ball one and one-half inches (1 1/2") in diameter | 12/11/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)7 | Yes | Yes | An enclosed stop switch meeting the requirements of ASME A17.1, 1995 edition, rule 210.2(e) shall be installed in the pit of all power elevators and be accessible from the pit access door. | 12/11/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | A permanent lighting fixture shall be provided in all pits to provide an illumination of not less than five (5) foot candles at the pit floor. The fixture switch shall be provided and accessible from the pit access door. | 11/21/2025 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | Yes | No | A fused disconnect means for all elevators shall be provided. Disconnect switch shall be located in the machine room and be readily accessible from the machine. | 12/11/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | No | 8.6.1.6.3 One of the carbon holders in the controller is damaged, and the carbon falls out. The carbon is being temporality held in place. Repair the carbon holder. | 7/24/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lights do not illuminate. | 7/24/2026 |