Inspection
Inspection Details
Equipment ID
9753
9753
Inspection Date
12/20/2024
12/20/2024
Inspection Type
Reinspection
Reinspection
Inspector Name
Sean Carmody
Sean Carmody
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
0127cbeb-f242-4ce2-ac10-e80d6eddde30
0127cbeb-f242-4ce2-ac10-e80d6eddde30
Location
Del Monte Apartments
5622 Delmar Blvd, St. Louis, MO
Phone: (314) 369-9441
Email: alex@opstl.com
5622 Delmar Blvd, St. Louis, MO
Phone: (314) 369-9441
Email: alex@opstl.com
Owner
Attn: Alex Oliver
Del Monte Apartments
5622 Delmar Blvd, St. Louis, MO 63112
Phone: (314) 369-9441
Alt Phone: (314) 221-3879
Email: alex@opstl.com
Del Monte Apartments
5622 Delmar Blvd, St. Louis, MO 63112
Phone: (314) 369-9441
Alt Phone: (314) 221-3879
Email: alex@opstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Jack Head is above the pump unit. Install pressure switch. | 2/24/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair inoperative emergency lights. | 9/24/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.3 - Operating control devices | 8.11.2.1.1(c) | No | No | Floor 1 call button is missing. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light does not work. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.35 - Supply Line and Shutoff Valve | 3.19 | No | No | Install shut off valve in the machine room. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.37 - Pressure Switch | 8.11.3.2.5 Pressure Switch (Re-Inspection) | Yes | No | Jack head is above the pump unit. Install pressure switch. | 3/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | No | No | Car top light does not work. | 2/24/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Handrails need to be installed on top of car. 2' gap between car top and back of hoistway. Side is open to other car. | 2/24/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | 1st-6th floor doors need pick-up rollers. | 2/24/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit needs to be cleaned. | 2/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 8.11.2.1.2(c) | No | No | Lighting in machine room is on a motion sensor in the hallway. Light needs to be on its own circuit. | 8/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Wiring on car top needs to be in conduit. | 8/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.3 Guards Between Adjacent Pits | No | No | Pit ladder needs to be mounted to the wall and not a free standing ladder. | 8/1/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean. Clean the pit. | 4/7/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/7/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational on main power and battery back-up. | 3/24/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 4/7/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | Pit shall have a permanently installed ladder. (Currently folding ladder) | 4/7/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | Yes | No | A permanent code compliant pit ladder shall be installed. (Repeat Violation) Re-Inspection now required. | 10/18/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | Yes | No | A permanent code compliant pit ladder shall be installed. (Repeat Violation) Re-Inspection still required. If not compliant, possible red tag to be issued. | 12/20/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Up to date operating certi?cate required in machine room. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit shall be dry and clean. (full of water) | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall work. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light shall work | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.4 Access to Pit | No | No | Walk in pit door shall be locked at all times. | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Fire service module shall be cover. |