Inspection
Inspection Details
Equipment ID
15224
15224
Inspection Date
12/19/2024
12/19/2024
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Tom Worsham
Tom Worsham
Relief Valve Pressure
NA
NA
Slide
Instantaneous
Instantaneous
Governor Rope Pull
25/225
25/225
Door Closing Force
16
16
External ID
8aeaa81c-ae7f-43f3-ab59-824eaa84ca8d
8aeaa81c-ae7f-43f3-ab59-824eaa84ca8d
Location
North Oaks Professional Bldg
23 N Oaks Plz, Normandy, MO
Phone: (314) 261-2777
23 N Oaks Plz, Normandy, MO
Phone: (314) 261-2777
Owner
Attn: North Oaks Group Inc
North Oaks Group Inc
23 N Oaks Plz, Ste 216, Normandy, MO 63121
Phone: (314) 261-2777
Email: northoaksgroup@yahoo.com
North Oaks Group Inc
23 N Oaks Plz, Ste 216, Normandy, MO 63121
Phone: (314) 261-2777
Email: northoaksgroup@yahoo.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (A) - Hoistways | (A)1 | Each passenger elevator hoistway landing shall be protected with a door or gate. The door or gate shall be of solid construction and shall guard the entire entrance. The 3rd floor hoistway door sight guard is missing and shall be replaced. | 1/25/2019 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Each passenger car shall have lighting inside the enclose of no less then 5 foot-candles. Bulbs and tubes shall be guarded to prevent breakage. | 1/25/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. | 8/31/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | The lobby hoist door is missing up thrust rollers. | 8/31/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 8/31/2021 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. | 8/31/2021 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective plate over it. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Equipment in the machine roon not being used in conjunction with the fuction or use of the elevator shall be removed. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | A current ABC fire extinguisher shall be provided in the machine room. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide code compliant machine room lighting. | |||
| MO Minimum : Elevators | (A) - Hoistways | (A)2 | x | The third floor hoistway door sight guard is missing and shall be replaced, the door shall be of solid construction and shall guard the entire entrance. | ||
| MO Minimum : Elevators | (I) - Pits | (I)2 | x | Buffers under the cars and counterweight shall be permanently fastened to the floor or their supporting beams. Spring buffer and support beam it is mounted to are severely rusted, and deterioration is so great that the buffer is loose and leaning out of plumb. | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | All landing doors shall be maintained to ensure safe and proper operation. Replace gibs on 2nd floor hoistway door and ensure the fire tabs on gibs are bent down to engage sill track. | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in the machine room. | |||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room door shall be self-closing and self-locking and operable from the interior space without use of a key. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | A current ABC type fire extinguisher shall be provided in the machine room. | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the machine room, in a noncombustible frame with a clear protective vision plate over it. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | A current maintenance control program (MCP) must be provided in the machine room. |