ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
3.4
|
Yes
|
No
|
3.4.1.3 - The hoistway pit refuge space area is to be clearly and permanently marked and identified as "REFUGE SPACE" and visible from the hoistway and the entrance to the pit as required by the Missouri elevator safety board.
|
3/22/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
3.4
|
Yes
|
No
|
3.4.1.6 - A sign with the words "DANGER LOW CLEARANCE" including the actual clearance dimension, shall be permanently posted on the power unit and shall be visible from within the pit and entrance to the pit as required by 3.4.1.6 and the Missouri elevator safety board.
|
3/22/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
No
|
No
|
All the on site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room.
|
5/10/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.31 - Relief Valves
|
8.11.3.1.2(n)
|
No
|
Yes
|
The system pressure shown on the screen is static (700 psi), so the relief pressure cannot be confirmed. Elevator Red Tagged. The low pressure test shall also be performed with the relief valve test.
|
3/22/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
3.4
|
Yes
|
No
|
3.4.1.3 - The hoistway pit refuge space area is to be clearly and permanently marked and identified as "REFUGE SPACE" and visible from the hoistway and the entrance to the pit as required by the Missouri elevator safety board.
|
1/13/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
3.4
|
Yes
|
No
|
3.4.1.6 - A sign with the words "DANGER LOW CLEARANCE" including the actual clearance dimension, shall be permanently posted on the power unit and shall be visible from within the pit and entrance to the pit as required by 3.4.1.6 and the Missouri elevator safety board.
|
1/13/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.2 - Car top light and outlet
|
2.14.7
|
No
|
No
|
Car top handrails shall be securely fastened. Only fastened on one side.
|
4/6/2026
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
8.11.2.1.5(j)
|
Yes
|
No
|
Guide rails shall be securely fastened to the building structure and properly supported. Rail clip missing at very top of the T-Rail
|
4/6/2026
|