Inspection
Inspection Details
Equipment ID
21868
21868
Inspection Date
1/16/2025
1/16/2025
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Dennis Smith
Dennis Smith
Mechanic Name
Jerry Reasoner
Jerry Reasoner
Relief Valve Pressure
N/A
N/A
Slide
4''
4''
Governor Rope Pull
N/A
N/A
Door Closing Force
20
20
External ID
6057544a-1fd6-4b7a-af6b-7358cb2f3421
6057544a-1fd6-4b7a-af6b-7358cb2f3421
Location
Holiday Inn Express
3600 Village Dr, St. Joseph, MO
Phone: (816) 232-2500
3600 Village Dr, St. Joseph, MO
Phone: (816) 232-2500
Owner
Attn: Scott Ehrhardt
Ehrhardts Jefferson City, LLC
2 Melgrove Ln, Hannibal, MO 63401
Phone: (816) 232-2500
Alt Phone: (573) 795-5642
Email: scottehrhardt@gmail.com
Ehrhardts Jefferson City, LLC
2 Melgrove Ln, Hannibal, MO 63401
Phone: (816) 232-2500
Alt Phone: (573) 795-5642
Email: scottehrhardt@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Post firefighter operating instructions next to hall fire keyswitch | 3/22/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Remove Phase 2 firefighter instructions next to hall fire keyswitch. Post Phase 1 firefighter instructions next to hall fire keyswitch. | 9/29/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters Emergency Operation: Monthly Testing | No | No | Test and log firefighter operation monthly | 9/29/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Wiring diagrams can not be stored on top of elevator. | 9/29/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(b)(1) | No | No | Provide written documentation on unique testing procedures, such as ascending car protection and unintended motion, and keep permanently on site. | 12/23/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light does not illuminate | 3/15/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing | 2.14.1.7 Railing and Equipment on Top of Cars | No | No | Install top of car handrail where distance from hoistway wall to the edge of the car top enclosure exceeds 12 inches | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(b)(1) | No | No | Written specific procedures for testing (i.e., ascending car protection , and unintended movement) need to be kept on site. | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4 Instructions for Locating Maintenance Records | No | No | Instructions for obtaining maintenance records need to be listed on the controller, or at the means necessary for test. | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(a)(1) | No | No | No written maintenance records on site for 2022 | 3/15/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.4.1(c)(3) | No | No | Install periodic test tag for annual test in 2022, and 5 yeat test performed Jan 2020 | 3/15/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Repair top of car blocking device. The blocking device does not engage with the rail mounted holding bracket | 12/20/2023 |