Inspection
Inspection Details
Equipment ID
7759
7759
Inspection Date
2/4/2025
2/4/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dennis Smith
Dennis Smith
Mechanic Name
Justin Kennedy
Justin Kennedy
Relief Valve Pressure
N/A
N/A
Slide
INSTANT
INSTANT
Governor Rope Pull
N/A
N/A
Door Closing Force
19
19
External ID
ae8de748-997f-4254-a027-66f16851d62d
ae8de748-997f-4254-a027-66f16851d62d
Location
Glore Museum
3406 Frederick Ave, St. Joseph, MO
Phone: (816) 364-1209
3406 Frederick Ave, St. Joseph, MO
Phone: (816) 364-1209
Owner
Attn: Glore Museum
Glore Museum
3406 Frederick Ave, St. Joseph, MO 64506
Phone: (816) 232-8471
Email: anita@stjosephmuseum.org
Glore Museum
3406 Frederick Ave, St. Joseph, MO 64506
Phone: (816) 232-8471
Email: anita@stjosephmuseum.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 8.6.4.11 | Yes | No | Need to shorten hoist ropes. Counterweight fully compresses buffer before car actuates top final limit switch. | 10/12/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not operate | 10/11/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state operating certificate inside machine room | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency phone does not operate | 10/6/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state operating certificate inside the machine room | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.2 Replacement of Suspension Means (Re-Inspection) | Yes | No | Replace undersized and rouged hoist ropes. | 10/4/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not operate | 10/4/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Post In Case of Fire signage next to hall button fixture at lobby landing | 12/9/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light does not illuminate | 12/9/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate not displayed in machine room | 12/9/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | emergency phone does not operate | 2/4/2025 |
| A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.6.3.2 (Re-Inspection) | Yes | No | Replace hoist ropes. Ropes are rouged and undersized | 2/4/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)5 | No | No | MOVER PIT LADDER TO HOISTWAY DOOR INTERLOCK SIDE | 12/9/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | IN CAR EMERGENCY PHONE NEED TO BE PROGRAMED | 12/9/2025 |