Inspection
Inspection Details
Equipment ID
13834
13834
Inspection Date
1/23/2025
1/23/2025
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
c0cbab06-db20-4e68-9c0a-ee46c8f4ef83
c0cbab06-db20-4e68-9c0a-ee46c8f4ef83
Location
Stadium Park East
200 S Broadway, St. Louis, MO
Phone: (314) 436-3087
Email: bill.vansambeek@intpark.com
200 S Broadway, St. Louis, MO
Phone: (314) 436-3087
Email: bill.vansambeek@intpark.com
Owner
Attn: Inter Park Holdings, LLC
Inter Park Holdings, LLC
111 W Jackson Blvd, Ste 1900, Chicago, IL 60604
Phone: (000) 000-0000
Email: bill.vansambeek@intpark.com
Inter Park Holdings, LLC
111 W Jackson Blvd, Ste 1900, Chicago, IL 60604
Phone: (000) 000-0000
Email: bill.vansambeek@intpark.com
Billing
Attn: Bill Van Sambeek
Inter Park Holdings, LLC
100 S 9th St, St. Louis, MO 63102
Phone: (000) 000-0000
Email: bill.vansambeek@intpark.com
Inter Park Holdings, LLC
100 S 9th St, St. Louis, MO 63102
Phone: (000) 000-0000
Email: bill.vansambeek@intpark.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 8/25/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light shall work. | 8/25/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Shorten the hoist ropes. | 8/25/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Car top light shall work. | 8/25/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Emergency stop switch shall be inoperable on Phase 2 fire service. | 3/31/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | This elevator is out of service. needs new ropes. | 3/29/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 4/29/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/8/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. | 12/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The fire service phase one key switch bezel shall be legible. | 12/8/2025 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)8 | Yes | No | The upper pit switch is seized in the run position and shall be repaired or replaced. | 9/6/2023 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | The in car stop key switch shall be rendered inoperative once the car is in motion while returning to the egress floor in phase one fire service. | 9/6/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 12/8/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 12/8/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communications device is not functioning and needs repair. | 1/23/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The fire service phase one key switch bezel shall be legible. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2 On-Site Documentation | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. |