Inspection
Inspection Details
Equipment ID
12720
12720
Inspection Date
1/28/2025
1/28/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
James Bishop
James Bishop
Relief Valve Pressure
570
570
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
18
18
External ID
ffd076c4-7598-4ff7-9814-12b87bcc1007
ffd076c4-7598-4ff7-9814-12b87bcc1007
Location
Boxes Inc./Mid America Display
111 Boulder Industrial Dr, Bridgeton, MO
Phone: (314) 678-5700
111 Boulder Industrial Dr, Bridgeton, MO
Phone: (314) 678-5700
Owner
Attn: David Glarner
Boulder, LLC
PO Box 179173, St. Louis, MO 63117
Phone: (314) 865-5700
Email: jane@glarnerstl.com
Boulder, LLC
PO Box 179173, St. Louis, MO 63117
Phone: (314) 865-5700
Email: jane@glarnerstl.com
Billing
Attn: Boxes Inc./Mid America Display
Boxes Inc./Mid America Display
111 Boulder Industrial Dr, Bridgeton, MO 63044
Phone: (314) 753-9052
Email: jane@glarnerstl.com
Boxes Inc./Mid America Display
111 Boulder Industrial Dr, Bridgeton, MO 63044
Phone: (314) 753-9052
Email: jane@glarnerstl.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | Yes | No | The door restrictor shall work. | 1/7/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency phone shall work. | 1/7/2020 |
| A17.1-1996 : Elevators | 2.11 - Disconnecting Means and Control | 210.4 | No | No | Label the disconnects with the feeder panel name, location and breaker numbers. | 3/26/2020 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | The oil cooler shall not be powered from the cab lighting circuit. | 3/26/2020 |
| A17.1-1996 : Elevators | 2.30 - Hydraulic Power Unit | 1004.2(b)(13) | No | No | The oil cooler shall be thermostatically controlled because the elevator has a viscosity cycle. | 3/26/2020 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | An ABC type fire extinguisher is required in the machine room. | 3/26/2020 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 2/14/2023 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test. | 2/14/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 2/14/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 1001.2(a)(17) | Yes | No | The auxiliary power lowering operation shall be functional. | 12/21/2022 |
| A17.1-1996 : Elevators | 3.8 - Top emergency exit | 1001.2(c)(12) | No | No | The emergency exit switch shall be operational. | 2/14/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | The auxiliary power lowering operation shall be functional. (2nd Notice) | 2/14/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 2/14/2023 |
| A17.1-1996 : Elevators | 3.8 - Top emergency exit | 204.1e | Yes | No | The emergency exit switch shall be operational. The actuator is missing. The fact that it's missing should prevent the car from running, but is not. This was also reported in 2021. This shall be corrected and re-inspected within 14 days. | 4/28/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | No updated State certificate in the machine room. | 12/22/2025 |