Inspection
Inspection Details
Equipment ID
10299
10299
Inspection Date
2/14/2025
2/14/2025
Inspection Type
Reinspection
Reinspection
Inspector Name
Paul Karrenbrock
Paul Karrenbrock
Mechanic Name
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
1e576793-c9f4-4b2d-9424-cca20e2976c2
1e576793-c9f4-4b2d-9424-cca20e2976c2
Location
Urshan College
155 Urshan Way, Wentzville, MO
Phone: (636) 229-7864
155 Urshan Way, Wentzville, MO
Phone: (636) 229-7864
Owner
Attn: Jaime Maddix
Urshan College
1151 Century Tel Dr, Wentzville, MO 63385
Phone: (936) 648-6388
Email: jmaddix@upci.org
Urshan College
1151 Century Tel Dr, Wentzville, MO 63385
Phone: (936) 648-6388
Email: jmaddix@upci.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency phone shall work. | 7/10/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | The elevator floor shall be maintained so that persons are not exposed to the hazards of tripping or falling. | 7/10/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lights shall be guarded to prevent breakage. | 7/10/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | Make hoistway door closers operational. | 7/10/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | The elevator floor shall be maintained so that persons are not exposed to the hazards of tripping or falling. | 7/10/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lights shall be guarded to prevent breakage. | 7/10/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | Make hoistway door closers operational. | 7/10/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 2/15/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light & alarm battery not working. Re-inspection required | 3/28/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Means of two-way communication are inoperable and shall be repaired, or replaced. | 2/14/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not working. Re-inspection required | 4/9/2026 |