Inspection
Inspection Details
Equipment ID
7859
7859
Inspection Date
2/11/2025
2/11/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dequarius Millett
Dequarius Millett
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
400
400
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
0d531759-56b8-474d-b4f1-d97f6aac9edd
0d531759-56b8-474d-b4f1-d97f6aac9edd
Location
Sigma Chemical-Cherokee Bldg
165 Cherokee St, St. Louis, MO
Phone: (314) 713-4729
165 Cherokee St, St. Louis, MO
Phone: (314) 713-4729
Owner
Attn: John Klipsch
Sigma Chemical
PO Box 14508, St. Louis, MO 63178
Phone: (314) 771-5765 Ext: 3968
Email: john.klipsch@milliporesigma.com
Sigma Chemical
PO Box 14508, St. Louis, MO 63178
Phone: (314) 771-5765 Ext: 3968
Email: john.klipsch@milliporesigma.com
Billing
Attn: John Klipsch
Sigma Chemical
3300 S 2nd St, St. Louis, MO 63118
Phone: (314) 771-5765 Ext: 3968
Email: john.klipsch@milliporesigma.com
Sigma Chemical
3300 S 2nd St, St. Louis, MO 63118
Phone: (314) 771-5765 Ext: 3968
Email: john.klipsch@milliporesigma.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Cab walls separating from platform because of corrosion and abuse. Repair. | 6/25/2020 | ||
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | Approx two cab wall sections separating from platform because of corrosion and abuse. Repair. | 6/25/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Car top light needs repair. | 6/25/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light needs repair. | 6/25/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | x | Front and rear car gate astrigals. | 12/5/2019 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | Clean pit. | 6/25/2020 | ||
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | Approximately two cab wall sections separating from platform because of corrosion and abuse. Repair | 6/25/2020 | ||
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Repair car top light. | 6/25/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Repair pit light. | 6/25/2020 | ||
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)1 | Approximately two cab wall sections separating from platform because of corrosion and abuse. Repair. | 6/25/2020 | ||
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Car top light inoperable. | 6/25/2020 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light switch fails to extinguish light when in "off" position. | 5/30/2023 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | 8.6.5.16.5 OSV NOT SEALED TEST DUE BEFORE NEXT INSP DUE 3/1/2022 | 5/30/2023 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | x | OSV is not sealed as noted in last inspection. Perform required testing, seal & tag within 90 days. Re-inspection required | 2/22/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light is not working | 5/30/2023 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room gate shall be self-closing. Repair existing closer on gate | 5/30/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency alarm shall work on auxiliary and normal power. Re-inspection required | 2/22/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Replace missing Phase I fire service sign by fire service keyswitch in hallway | 5/30/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | Car gate reversing edges on both sides do not work. Repair same. Re-inspection required | 2/22/2023 | |
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light is not working | 5/30/2023 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room gate shall be self closing, needs repair | 5/30/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency alarm shall work on auxiliary & normal power. Re-inspection required | 2/22/2023 | |
MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Replace missing Phase I fire service sign by fire service keyswitch in hallway | 5/30/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | x | Car gate reversing edges on both sides do not work, repair same. Re-inspection required | 2/22/2023 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current State Elevator Certificate. | 5/18/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Replace missing hoistway/car door/gate pull straps, as needed. | 5/18/2023 | ||
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)2 | Hoistway door at Q3 floor has welded spacer. Welds have broken, spacer is bent, repair as needed. | 5/18/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces | Machine room/space has water dripping/splashing various spots, provide means to prevent. | 5/18/2023 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | Provide guard on bulbs in the elevator machine room, to prevent accidental contact or breakage. | 5/18/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Provide Code compliant fire extinguisher in the elevator machine room. | 5/18/2023 | ||
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Provide testing of Phase I operations, no key. | 5/12/2023 | |
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Provide testing of Phase II operations, no key. | 5/12/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Replace missing phone door handle. | 5/18/2023 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Provide existing pit light to work. | 5/18/2023 | ||
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Fire service Phase II shall work. Re-inspection required | 2/27/2024 | |
MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | Repair or replace non working light in car. | 9/24/2024 |