Inspection
Inspection Details
Equipment ID
1434
1434
Inspection Date
2/6/2025
2/6/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Nathaniel Smith
Nathaniel Smith
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
f2b26897-7e4c-4295-96a1-1710898fb476
f2b26897-7e4c-4295-96a1-1710898fb476
Location
Macy's- South County
10 S COUNTY CENTER WAY, SAINT LOUIS, MO
Phone: (314) 892-0110
10 S COUNTY CENTER WAY, SAINT LOUIS, MO
Phone: (314) 892-0110
Owner
Attn: TSG PROPERTIES
TSG PROPERTIES
237 Woodbridge Center Dr, 3rd Flr, Woodbridge, NJ 07095
Phone: (314) 471-4975
Email: PRESS@BPRETAIL.COM
TSG PROPERTIES
237 Woodbridge Center Dr, 3rd Flr, Woodbridge, NJ 07095
Phone: (314) 471-4975
Email: PRESS@BPRETAIL.COM
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Clean down trust | 2/14/2020 |
| conversion | conversion | conversion - red tag | Yes | Yes | Failed Brake torque test --Red Tagged | 5/24/2018 |
| conversion | conversion | n/a | No | No | Complete annual inspection | 2/14/2020 |
| conversion | conversion | n/a | No | No | Replace steps with chipped edge | 2/14/2020 |
| conversion | conversion | n/a | No | No | Complete annual test | 2/14/2020 |
| conversion | conversion | n/a | No | No | Clean down trust | 2/14/2020 |
| conversion | conversion | n/a | No | No | Replace steps with chipped edges | 2/14/2020 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | No | No | Need full truss clean down | |
| A17.1-2016 : Elevators | 7.19 - Maintenance records | 8.6.1.2.1(b) | No | No | Need maintenance control plan and place on controller | |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.6 Steps | Yes | No | Replace broken (chipped) step treads | 10/17/2023 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post certificate in machine room |