Inspection
Inspection Details
Equipment ID
12199
12199
Inspection Date
1/30/2025
1/30/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
NA
NA
Slide
51.5"
51.5"
Governor Rope Pull
TBD
TBD
Door Closing Force
TBD
TBD
External ID
dce1bb0b-c73f-4faa-a826-5cc146dbc75c
dce1bb0b-c73f-4faa-a826-5cc146dbc75c
Location
1010 Market
1010 Market St, St. Louis, MO
Phone: (314) 621-8676
1010 Market St, St. Louis, MO
Phone: (314) 621-8676
Owner
Attn: AKNO 1010 Market Street St. Louis, LLC
AKNO 1010 Market Street St. Louis, LLC
1010 Market St, Ste 580, St. Louis, MO 63101
Phone: (314) 584-6240
Alt Phone: (314) 621-8676 Ext: 26
Email: donna.apollo@colliers.com
AKNO 1010 Market Street St. Louis, LLC
1010 Market St, Ste 580, St. Louis, MO 63101
Phone: (314) 584-6240
Alt Phone: (314) 621-8676 Ext: 26
Email: donna.apollo@colliers.com
Billing
Attn: AKNO 1010 Market Street St. Louis, LLC
AKNO 1010 Market Street St. Louis, LLC
1010 Market St, Ste 580, St. Louis, MO 63101
Phone: (314) 584-6240
Alt Phone: (314) 621-8676 Ext: 26
Email: donna.apollo@colliers.com
AKNO 1010 Market Street St. Louis, LLC
1010 Market St, Ste 580, St. Louis, MO 63101
Phone: (314) 584-6240
Alt Phone: (314) 621-8676 Ext: 26
Email: donna.apollo@colliers.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Firefighters Phase II instructions needs to be legible | 8/17/2018 |
| conversion | conversion | n/a | No | No | Pit ladder is not safely accessible | 8/17/2018 |
| conversion | conversion | n/a | No | No | Car top needs to be cleaned | 8/17/2018 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 3/29/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove water from pit | 3/29/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Repair fire service phase II operation | 8/23/2021 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Fire Service Phase 2 still down | 9/28/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 4/29/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Repair phase 2 fire service when tuened off in the car, it returns to the first floor and the car doors do not open and car does not return to phase 1 | 8/31/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | Yes | Reinspection checking phase 2 Fire service. No repairs made red tagged unit. | 9/26/2023 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Full load slide test failed unit red tagged out of service | 1/30/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Testing incomplete: Only tested slide & smashed car buffer, problems with running equipment. The annual inspection and category 5 testing shall be completed. Note: Unit remains locked out of service until category 5 testing is completed as slide was cited as non-compliant in 2023. | 2/15/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Fire service Phase 1 & 2 need to be tested when remaining units are tested. It is also unknown if the elevators operate on an emergency generator. If this unit is equipped to operate on the emergency generator, it shall be tested. | 4/29/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Pit shall be kept clean. | 7/7/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Top of car shall be kept clean. | 7/7/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | State operating certificate is expired. | 7/7/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Buzzer shall be repaired. | 7/7/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room. |