Inspection
Inspection Details
Equipment ID
203
203
Inspection Date
12/7/2018
12/7/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
Thomas Moore
Thomas Moore
Relief Valve Pressure
480
480
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
4d867eb3-b808-4f92-8211-2519fc4fbb3e
4d867eb3-b808-4f92-8211-2519fc4fbb3e
Location
Marymount Manor
313 AUGUSTINE RD, EUREKA, MO
313 AUGUSTINE RD, EUREKA, MO
Owner
Mary Mount Manor
313 AUGUSTINE RD, EUREKA, MO 63025-1935
313 AUGUSTINE RD, EUREKA, MO 63025-1935
Billing
Attn: Mary Mount Manor
313 AUGUSTINE RD, EUREKA, MO 63025-1935
313 AUGUSTINE RD, EUREKA, MO 63025-1935
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | No | No | Alarm bell is not working. | 10/16/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Fire service call cancel not working. When call cancel button is pushed, car stops in between floors. | 10/16/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Phone and alarm bell shall work. Ten working days to correct or elevator shall be red-tagged. | 11/23/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Fireman's Phase II call cancel, when pushed to cancel call elevator stops, then levels into the next floor. | 11/23/2020 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)4 | No | No | Cylinder needs to be repacked. | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit shall be clean and dry. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | No | No | Door force too high, should be less than 30 pds. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Use of oil recovery system by automatic means prevents proper monitoring of packing glands and seals. | |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Car stopped in the middle of run when car cancel was pushed. Only elevator in building. Red tagged. Repair ASAP. | 9/27/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm not working. | 9/17/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work | 9/17/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell in elevator cab does not work | 9/17/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell in elevator cab not working | 8/4/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace missing / worn cab steadier's | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Need to provide up-to-date wiring diagrams as part of the MCP | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Yes | No | Post current State Elevator Certificate. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Car top door operator is missing cover, provide. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide existing machine room light to work. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean the car top. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Machine room ceiling has water damage, repair or replace as needed. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces | No | No | Abate black mold on machine room ceiling. | |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | No | No | OSV is sealed, no tag. Provide testing. Record results. |