|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.17 - Drive machine brake
|
8.11.2.1.2(o)
|
Yes
|
Yes
|
Machine brake would not hold 125% of rated load. Elevator red-tagged and locked off for repairs. Category 5 portion of testing is complete, except for the machine brake. All other inspections items still need to be completed.
|
3/15/2019
|
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
Yes
|
No
|
Category 1 inspections items still need testing as of 3/15/2019 re-inspection.
|
4/19/2019
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
No
|
No
|
A current MO state operating certificate shall be displayed in the elevator machine room.
|
4/9/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
No
|
No
|
Provide a code compliant MCP including on-site documents.
|
4/9/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
The in car emergency telephone shall be operational.
|
4/5/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.17 - Drive machine brake
|
8.6.4.19.11 A17.1 2016 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake
|
Yes
|
No
|
The means to manually release the brake shall operate properly.
|
4/5/2021
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
4.2 - Hoistway doors
|
8.11.2.1.4(b)
|
Yes
|
No
|
Fire stop is missing from bottom of hoistway doors.
|
3/29/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.7 - Fire Extinguisher
|
8.6.1.6.5
|
No
|
No
|
The fire extinguisher is expired.
|
4/5/2022
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.5 - Car lighting and receptacles
|
8.6.4.15 Emergency Lighting
|
Yes
|
No
|
2.14.7.2.2 - Automatic operation of the car lights shall be arranged to turn off the lights only when the following conditions exist for not less than 5 minutes: (a) the car is at a floor (b) the doors are closed (c) there is no demand for service (d) the car is on automatic operation. Momentary interruption of any of the above conditions shall cause the car lights to turn on. Note: The car lighting branch circuit is being controlled and disconnected by a building system separate from the elevator control. This system is removing power based on time, and not the conditions required by A17.1 2.14.7.2.2. Additionally, when the branch circuit power is removed, the auxiliary lights in the car are being activated. The auxiliary light system is designed to operate on battery power for four hours in the event of lighting branch circuit failure. Having this power removed discharges the battery. When the battery is discharged, the elevator control will take the elevator out of service until the battery is re-charged.
|
4/11/2023
|