Inspection
Inspection Details
Equipment ID
154
154
Inspection Date
12/18/2018
12/18/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gerald Glynn
Gerald Glynn
Mechanic Name
Jeremiah Dugger
Jeremiah Dugger
Relief Valve Pressure
440
440
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
24b2640e-a45b-4d7f-ace0-3705f2569d26
24b2640e-a45b-4d7f-ace0-3705f2569d26
Location
Great Southern Bank
1451 E BATTLEFIELD ST, SPRINGFIELD, MO
1451 E BATTLEFIELD ST, SPRINGFIELD, MO
Owner
Great Southern Bank
1451 E BATTLEFIELD ST, SPRINGFIELD, MO 65804-3701
1451 E BATTLEFIELD ST, SPRINGFIELD, MO 65804-3701
Billing
Attn: Great Southern Bank
PO BOX 2451, SPRINGFIELD, MO 65801-2451
PO BOX 2451, SPRINGFIELD, MO 65801-2451
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Pit scavenger pump will be removed | 8/9/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location | 8/12/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car Door restrictor shall work. Bracket missing | 8/12/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location | 8/12/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car Door restrictor shall work. Bracket missing | 8/12/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No maintenance records | 2/23/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | To be tested monthly | 2/23/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 2/23/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | H4. Machine room shall not be used to store non-elevator related items. ( fluorescent lamps, ceiling tiles, AC parts, ) | 2/23/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | B(11): 2-way communication device shall work and give proper location, 1st and 2nd numbers: No Answer. must be answered 24/7. (Reported as repaired previously , but not) REINSPECTION REQUIRED, 30days | 12/20/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | G(1) Car Door restrictor shall work. Wrong bracket installed. (Reported as repaired previously , but not) REINSPECTION REQUIRED, 30days | 12/20/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | G(1)/A17.1-2016:8.6.1.4 :Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) . | 2/23/2023 |