Inspection
Inspection Details
Equipment ID
17845
17845
Inspection Date
3/14/2025
3/14/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Timothy Trout
Timothy Trout
Mechanic Name
Michael Loftin
Michael Loftin
Relief Valve Pressure
580
580
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
F20 R26
F20 R26
External ID
e3b9d239-fa5d-4b6c-8f2b-e84a3f8191ca
e3b9d239-fa5d-4b6c-8f2b-e84a3f8191ca
Location
Oasis Inn
2546 N Glenstone Ave, Springfield, MO
Phone: (417) 866-5253
2546 N Glenstone Ave, Springfield, MO
Phone: (417) 866-5253
Owner
Attn: Oasis Inn
Prime Inc
2550 N Glenstone Ave, Springfield, MO 65803
Phone: (000) 000-0000
Email: gmears@springfieldoasis.com
Prime Inc
2550 N Glenstone Ave, Springfield, MO 65803
Phone: (000) 000-0000
Email: gmears@springfieldoasis.com
Billing
Attn: Guy Mears
Oasis Inn
2546 N Glenstone Ave, Springfield, MO 65803
Phone: (417) 520-7781
Email: gmears@springfieldoasis.com
Oasis Inn
2546 N Glenstone Ave, Springfield, MO 65803
Phone: (417) 520-7781
Email: gmears@springfieldoasis.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | Replace the emergency alarm battery. | 1/28/2026 | ||
| conversion | conversion | n/a | Obtain and display a current state operating certificate in the machine room. | 1/28/2026 | ||
| conversion | conversion | n/a | Check out the operation of the sump as there seems to not be any plower to the pump. | 1/28/2026 | ||
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | Replace the emergency light battery. | 1/28/2026 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Repair the emergency phone there is no dial tone. | 2/6/2020 | |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display a current state operating certificate in the machine room | 1/28/2026 | ||
| A17.1-1996 : Elevators | 2.6 - Ventilation | 1001.2(b)(6) | Repair the AC unit in the machine room as it does not work | 1/28/2026 | ||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Obtain and display a current state operating certificate in the machine room. | 1/28/2026 | ||
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.2-211.8 | x | x | Replace the fire service recall switch as it will not recall the elevator | 1/31/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Obtain and display a current state operating certificate in the machine room | 1/28/2026 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Obtain and display a current state operating certificate in the machine room. | 1/28/2026 | ||
| A17.1-1996 : Elevators | 2.6 - Ventilation | 1001.2(b)(6) | Repair the non working AC unit in the machine room | 1/28/2026 | ||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Obtain and display a current state operating certificate in the machine room | |||
| A17.1-2016 : Elevators | 7.19 - Maintenance records | 8.6.1.2.1(a) | Provide an MCP in the machine room | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Obtain and display a current operating certificate in the machine room | |||
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Obtain and display a current state operating certificate in the machine room. |