Inspection
Inspection Details
Equipment ID
21347
21347
Inspection Date
3/17/2025
3/17/2025
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Benjamin Williams
Benjamin Williams
Relief Valve Pressure
Na
Na
Slide
See report
See report
Governor Rope Pull
30/480
30/480
Door Closing Force
25
25
External ID
04fb1e54-4fd1-46df-a376-47320f5622ae
04fb1e54-4fd1-46df-a376-47320f5622ae
Location
Vaterott Bldg
10449 Saint Charles Rock Rd, St. Ann, MO
Phone: (314) 482-7025
10449 Saint Charles Rock Rd, St. Ann, MO
Phone: (314) 482-7025
Owner
Attn: Christal Brown
CVF Real Estate
10143 Paget Dr, St. Louis, MO 63132
Phone: (636) 642-0186
Email: christalb@cfvatterott.com
CVF Real Estate
10143 Paget Dr, St. Louis, MO 63132
Phone: (636) 642-0186
Email: christalb@cfvatterott.com
Billing
Attn: Maintenance
CVF Real Estate
10143 Paget Dr, St. Louis, MO 63132
Phone: (636) 642-0186
Email: maintenance@cfvatterott.com
CVF Real Estate
10143 Paget Dr, St. Louis, MO 63132
Phone: (636) 642-0186
Email: maintenance@cfvatterott.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Test not complete. Car failed 125% brake test. Also, car was not running contract speed. | |
| conversion | conversion | n/a | No | No | Per Larry Watson, he gave Kone two weeks to complete repairs. | |
| conversion | conversion | n/a | No | No | Test not complete. Car failed 125% brake test. Also, car was not running contract speed. | |
| conversion | conversion | n/a | No | No | Per Larry Watson, he gave Kone two weeks to complete repairs. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Car traveling at 16% of contract speed. Determine cause and perform full load safety test for proper slide. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 3/2/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide MCP | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Expired | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the state operating certificate shall be displayed in the machine room | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Car speed is rated at 200 fpm. Up full load =70fpm, down=150. Provide car to run at contract speed. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Car safety not tested. Provide car to run at contract speed. Cat 5 safety test required. Record slide. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide machine room door to be self locking. |