Inspection
Inspection Details
Equipment ID
24912
24912
Inspection Date
3/19/2025
3/19/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Elder
Michael Elder
Mechanic Name
Clinton Severs
Clinton Severs
Relief Valve Pressure
580
580
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
67d20d5d-6af3-490e-86a9-ce6c04dadab2
67d20d5d-6af3-490e-86a9-ce6c04dadab2
Location
St. Paul's Lutheran Church
207 N Owen St, California, MO
Phone: (573) 796-2735
207 N Owen St, California, MO
Phone: (573) 796-2735
Owner
Attn: St. Paul's Lutheran Church
St. Paul's Lutheran Church
207 N Owen St, California, MO 65018
Phone: (573) 796-2735
Email: office@stpaulslutheran1860.com
St. Paul's Lutheran Church
207 N Owen St, California, MO 65018
Phone: (573) 796-2735
Email: office@stpaulslutheran1860.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing | 2.4 | Yes | Yes | 5.2.1.4.4. low clearance | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 2.4.2 | Yes | No | 5.2.1.4.2. no protection | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | No | No | 5.2.1.1 not solid or fire proof | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.1.3.3 | No | No | 5.2.1.7.1. not solid or fire proof | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.1 - Car platform guard | 2.15.9 | No | No | 5.2.1.15.2. no platform guard | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | phone not working, no emergency light/bell | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.34 - Flexible Hydraulic Hose and Fitting Assemblies | 8.11.3.1.2 (q) | No | No | Rubber hose out of date | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | No | No | 5.2.1.12. Hoistway wiring not in conduit or protected. Car light not on single circuit | 1/16/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.4 - Hoistway door locking devices | 2.12 | Yes | No | 5.2.1.12. runs with doors open, contacts at each floor no wired right | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.2 - Hoistway doors | 2.12.7 | Yes | Yes | 2.5.7.5.1. more than 5 inches between hoist door and car gate when door is closed | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.3 - Final and emergency terminal stopping devices | 2.25.3 | Yes | Yes | 5.2.2.13. top final | 10/1/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | not self closing or locking | 1/16/2026 |