Inspection
Inspection Details
Equipment ID
5804
5804
Inspection Date
2/26/2025
2/26/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Scott Bachman
Scott Bachman
Relief Valve Pressure
290
290
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
27
27
External ID
eddfa8e7-c872-430b-b158-e0c03b254679
eddfa8e7-c872-430b-b158-e0c03b254679
Location
Hampton Inn- Maryland Heights
2454 Old Dorsett Rd, Maryland Heights, MO
Phone: (314) 298-7878
2454 Old Dorsett Rd, Maryland Heights, MO
Phone: (314) 298-7878
Owner
Attn: Double Star Maryland Heights LLC
Double Star Maryland Heights LLC
113 Eston Way, Mount Juliet, TN 37122
Phone: (000) 000-0000
Email: operations@doublestarmanagement.com
Double Star Maryland Heights LLC
113 Eston Way, Mount Juliet, TN 37122
Phone: (000) 000-0000
Email: operations@doublestarmanagement.com
Billing
Attn: Hampton Inn - Maryland Heights
Hampton Inn - Maryland Heights
2454 Old Dorsett, Maryland Heights, MO 63043
Phone: (314) 298-7878 Ext: 605
Email: operations@doublestarmanagement.com
Hampton Inn - Maryland Heights
2454 Old Dorsett, Maryland Heights, MO 63043
Phone: (314) 298-7878 Ext: 605
Email: operations@doublestarmanagement.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | Door restrictor needs to work. Reinspection required. 1.18 | 10/14/2019 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Static test failed, oil leaking through valve. 2.42 | 9/10/2020 | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone not working. 1.6 | 10/14/2019 | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | x | Car door restrictor does not work. | 6/9/2020 | |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Fire service Phase I key switch is labeled incorrectly. Repair and reinspect within 30 days. | 6/9/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | OSV is not sealed and must have a cat 5 weight test performed within 90 days or less | 12/1/2021 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Unit failed 15 minute standing test, suspect leaking back through control valve and machine room shut off. Did not leak down when pit shutoff valve closed | 9/21/2021 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Unit failed 15 minute standing test, suspect leak back through control valve and machine room shut off. Did not leak down when pit shut off valve closed | 5/19/2022 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Door operator needs repair. | 4/10/2025 | ||
| MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | x | The hall fire hat jewel must illuminate when on fire service operation. | ||
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be kept on site. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational on auxiliary power. | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The machine room shall have a self-closing and self-locking door and shall be operable from the interior space without the use of a key. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | There are two red key-switches marked "stop" in the car operating panel. Only one is operable. The inoperable key-switch shall be replaced or repaired and marked for the function it serves or shall be removed and the hole covered. | |||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | x | The car leaked excessively during the static test required by A17.1 2016 8.6.5.14.2. It was determined that the oil is leaking back into the tank. Unit RED-TAGGED and not to be returned to service until repaired and tested. |