Inspection
Inspection Details
Equipment ID
19104
19104
Inspection Date
3/26/2025
3/26/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Brant Willtrout
Brant Willtrout
Relief Valve Pressure
530
530
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
23
23
External ID
9f76537a-99a1-4caa-ae70-196bafea4204
9f76537a-99a1-4caa-ae70-196bafea4204
Location
P T Bosley Senior Estates
4301 Warne Ave, St. Louis, MO
Phone: (314) 534-4700
4301 Warne Ave, St. Louis, MO
Phone: (314) 534-4700
Owner
Attn: Priscilla Redd-Brown
P T Bosley Senior Estates
4301 Warne Ave, St. Louis, MO 63107
Phone: (314) 534-4700
Email: nmcwilliams@voa.org
P T Bosley Senior Estates
4301 Warne Ave, St. Louis, MO 63107
Phone: (314) 534-4700
Email: nmcwilliams@voa.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Clean pit | 7/5/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | repair phone in car | 7/27/2018 |
| conversion | conversion | n/a | No | No | In car stop.run switch broken | 7/5/2018 |
| conversion | conversion | n/a | No | No | Replace missing fire service call cancel button in car | 7/5/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency phone not working | 12/21/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) | No | No | need testing procedures in the MCP on or before 1/1/22 | 1/9/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone still not working | 1/11/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair phone in car | 12/19/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 1/9/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 1/9/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | Perform 5 year overspeed valve test within 30 days | 3/18/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair phone in car. Reinspection required within 30 days | 3/26/2025 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair Phone in the Car | 6/16/2026 |