Inspection
Inspection Details
Equipment ID
21597
21597
Inspection Date
3/26/2025
3/26/2025
Inspection Type
Alteration
Alteration
Inspector Name
Bradley Rasnake
Bradley Rasnake
Mechanic Name
Christian Schickedanz
Christian Schickedanz
Relief Valve Pressure
590
590
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
Na
Na
External ID
d42da339-4daa-4a1f-9166-16d1a8d9f84c
d42da339-4daa-4a1f-9166-16d1a8d9f84c
Location
Park Place
2000 Boardwalk Place Dr, O'Fallon, MO
Phone: (636) 625-2906
2000 Boardwalk Place Dr, O'Fallon, MO
Phone: (636) 625-2906
Owner
Attn: CHP O'Fallon LLC/ Gary Dixon
CHP O'Fallon LLC
2002 Boardwalk Place Dr, O'Fallon, MO 63368
Phone: (314) 226-6636
Email: gdixon@parkplacewinghaven.com
CHP O'Fallon LLC
2002 Boardwalk Place Dr, O'Fallon, MO 63368
Phone: (314) 226-6636
Email: gdixon@parkplacewinghaven.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Elevator Pit needs to be clean and dry | 5/27/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Alarm Bell shall work | 3/14/2019 |
| conversion | conversion | n/a | No | No | Both Hydraulic cylinder need repacking | 5/27/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - n/a | n/a | No | No | Remove oil from pit. | 5/27/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.11 - Plunger and Cylinder | 3.18 | No | No | Cylinders are leaking oil. Packing needs to be replaced. REINSPECTION REQUIRED. | 5/27/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit to remove debris, water and/or oil and address sources. Oil dry is all over pit | 7/1/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machinery spaces, machine rooms, control spaces, and control rooms. Remove used oil and used oil drying compound. | 1/10/2023 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | A Packing on right side piston is leaking oil. Identify and correct the cause of excessive oil leakage. | 1/10/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove oil/oily pads on the pit floor and sump hole. All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. | 1/1/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | All pits shall be kept dry, clean, and free of equipment or material not relating to the operation of the elevator. There are oil soaked pads and oil on the pit floor. | 4/23/2026 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | Where pressure piping, valves, and cylinders use packing glands or seals, they shall be examined and maintained to prevent excessive loss of fluid. | 4/23/2026 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | Oil collection containers shall not be allowed to overflow. | 4/23/2026 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.4.19.6 | Yes | No | The audible buzzer, which activates when the elevator initiates fire fighter's operation, is not functioning. | 4/23/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | The plastic border around the COP is broken off creating an opening around the COP. The electrical wiring is exposed. | 4/23/2026 |