Inspection
Inspection Details
Equipment ID
23849
23849
Inspection Date
10/31/2017
10/31/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Coder
Wayne Coder
Mechanic Name
Relief Valve Pressure
n/a
n/a
Slide
1"
1"
Governor Rope Pull
50/200
50/200
Door Closing Force
24
24
External ID
Location
Bunge North America
1391 Timberlake Manor Pky, Chesterfield, MO
Phone: (314) 292-2000
1391 Timberlake Manor Pky, Chesterfield, MO
Phone: (314) 292-2000
Owner
MHBK Leasing & Finance
1251 Avenue of the Americas, New York, NY 10020
1251 Avenue of the Americas, New York, NY 10020
Billing
Attn: MHBK Leasing & Finance
1251 Avenue of the Americas, , NY 10020
1251 Avenue of the Americas, , NY 10020
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | The governor rope size is 6mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | No | No | 2.20 - The hoist rope is 8mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Test emergency power. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 2.18.5 | No | No | The governor rope size is 6mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 2.20 | No | No | 2.20 - The hoist rope is 8mm. Code requires 9.5mm. Customer shall apply for a variance. | 12/14/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.1.1(q) | Yes | No | Emergency power shall be tested. | 10/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.10 - Numbering of elevators, machines, and disconnect switches | 2.29.1 | No | No | Elevator number on COP shall be correct. Currently says elevator #1 but it is elevator #3. | 11/25/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 11/8/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.6 - Governor-rope tension devices | 8.11.2.1.5(g) | No | No | The tail sheave switch shall be wired per the manufactures’ specifications. | 12/17/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Emergency power operation shall be tested. | 10/8/2025 |