Inspection
Inspection Details
Equipment ID
14747
14747
Inspection Date
4/4/2025
4/4/2025
Inspection Type
Reinspection
Reinspection
Inspector Name
Dequarius Millett
Dequarius Millett
Mechanic Name
Thomas Suedkamp
Thomas Suedkamp
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
N/A
N/A
External ID
909a27f5-aac3-477b-8673-a6e430bcd143
909a27f5-aac3-477b-8673-a6e430bcd143
Location
Residenses at Forest Park Hotel
4910 W Pine Blvd, St. Louis, MO
Phone: (314) 367-3300
Email: denise@2bresidential.com
4910 W Pine Blvd, St. Louis, MO
Phone: (314) 367-3300
Email: denise@2bresidential.com
Owner
Attn: Residences at Forest Park
RL Manager LLC
4910 W Pine Blvd, St. Louis, MO 63108
Phone: (314) 369-4105
Email: denise@2bresidential.com
RL Manager LLC
4910 W Pine Blvd, St. Louis, MO 63108
Phone: (314) 369-4105
Email: denise@2bresidential.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | emergency alarm and phone back-up battery inoperative repair | 11/11/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm and phone back up battery inoperative. Repair | 10/18/2019 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Maintenance control program shall include written records and procedures for inspections in machine room. | 11/11/2020 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Fire extinguisher in machine room needs to be serviced. | 11/11/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm does not work | 7/25/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm inoperable, does not work on emergency power or regular power. Re-inspection required | 4/1/2025 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Car safeties are stopping the car to fast. Slide shall have a minimum of 2 inches and a maximum of 16 inches. Slide is 1 inch. Car has been red tagged and removed from service until the safeties are adjust and reinspected | 4/4/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell is inoperable | 4/4/2025 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Car safeties are stopping the car to fast. Slide shall have a minimum of 2 inches and a maximum of 16 inches. Slide is 1 inch. Car has been red tagged and removed from service until the safeties are adjust and reinspected | 6/25/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell is inoperable | 6/25/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell is inoperable. Re-inspection required |