Inspection
Inspection Details
Equipment ID
19681
19681
Inspection Date
3/14/2025
3/14/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
27
27
External ID
f554026e-fac0-49d5-b0fd-b2a0a2eb79f5
f554026e-fac0-49d5-b0fd-b2a0a2eb79f5
Location
Old Laclede Gas & Light Building
1017 Olive St, St. Louis, MO
Phone: (314) 436-7626
1017 Olive St, St. Louis, MO
Phone: (314) 436-7626
Owner
Attn: Double Delta Arizona LLC
Double Delta Arizona LLC
1017 Olive St, Ste 1000, St. Louis, MO 63101
Phone: (000) 000-0000
Double Delta Arizona LLC
1017 Olive St, Ste 1000, St. Louis, MO 63101
Phone: (000) 000-0000
Billing
Attn: The Laclede Gas Light Company
The Laclede Gas Light Company
1017 Olive St, Ste 802, St. Louis, MO 63101
Phone: (314) 436-9019
Email: diana@hwprigging.com
The Laclede Gas Light Company
1017 Olive St, Ste 802, St. Louis, MO 63101
Phone: (314) 436-9019
Email: diana@hwprigging.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Repair phone in car t include replacing back up battery | 5/30/2019 |
| conversion | conversion | n/a | No | No | Post current State certificate in Machine room | 9/14/2020 |
| conversion | conversion | n/a | No | No | All fire Service Keys in building to be keyed the same | 9/14/2020 |
| A17.1-1996 : Elevators | 1.8 - Door closing force | 1001.2(a)(8) | Yes | No | adjust car door pressure--excess force | 4/25/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair low volumn of phone | 5/30/2019 |
| A17.1-1996 : Elevators | 5.10 - Compensating chains, ropes, and sheaves | 202.4 | Yes | No | Reinsall hoist rops on coutrweight fram sheave/ Test Fire Service | 5/30/2019 |
| A17.1-1996 : Elevators | 1.8 - Door closing force | 112.4(b) | Yes | No | test door closing orce | 5/30/2019 |
| A17.1-1996 : Elevators | 1.8 - Door closing force | 112.4(b) | Yes | No | adjust car door pressure..excessive force// | 4/29/2020 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.8 Switch Keys | No | No | All fire Service Keys in building to be keyed the same--Reinspection required | 9/14/2020 |
| A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.2-211.8 | Yes | Yes | Repair Fire Service for elevator to respond to the 2nd floor when primary smoke detector is activated--Reinspection required within 30 days | 9/10/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair phone in car--Reinspection required | 9/10/2020 |
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3d | No | No | Make machine room door self closing and locking | 9/14/2020 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Repair light in car--missing cover | 9/14/2020 |
| A17.1-1996 : Elevators | 1.8 - Door closing force | 1002.2(h) | Yes | No | Adjust car door operator--excess car door force--Reinspection required | 9/10/2020 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 7/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Need a maintenance control program on site posted on controller | 7/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Bottome left counterweight roller bad needs replacing | 5/23/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Complete CAT 5 testing | 8/26/2024 |
| A17.1-1996 : Elevators | 4.2 - Hoistway doors | 110 | Yes | No | Replace any missing fire tabs on hoistway doors. Levels (B, 1, M) | 7/18/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. | |
| A17.1-1996 : Elevators | 3.28 - Counterweight and counterweight buffer | 201 | No | No | Replace multiple damaged counterweight roller guides. | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergecy phone shall establish 2-way communication. |