Inspection
Inspection Details
Equipment ID
1870
1870
Inspection Date
4/10/2025
4/10/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dequarius Millett
Dequarius Millett
Mechanic Name
Kevin Liles
Kevin Liles
Relief Valve Pressure
520
520
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
17
17
External ID
8212a40e-72b1-418a-8bbc-1f769b96e347
8212a40e-72b1-418a-8bbc-1f769b96e347
Location
Gibson Elementary School
9926 FONDA DR, SAINT LOUIS, MO
Phone: (314) 869-4845
9926 FONDA DR, SAINT LOUIS, MO
Phone: (314) 869-4845
Owner
Attn: Riverview Gardens School District
Riverview Gardens School District
1370 Northumberland Dr, St. Louis, MO 63137
Phone: (314) 869-2505
Email: finance@rgsd.k12.mo.us
Riverview Gardens School District
1370 Northumberland Dr, St. Louis, MO 63137
Phone: (314) 869-2505
Email: finance@rgsd.k12.mo.us
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | Perform OSV test on or before next annual inspection. | 7/30/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean debris out of pit | 5/31/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher is expired, have serviced or replaced | 5/15/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A copy of the current operating certificate shall be displayed in the machine room | 5/15/2026 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)1 | Yes | No | Stop switch shall be repaired in the car operator panel. Re-inspection required | 4/10/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current state operating certificate shall be displayed in elevator machine room. | 5/15/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit conditions shall be clean, dry, and clear of all debris. | 5/15/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm inoperable, repair or replace as needed. | 5/21/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Emergency lighting inoperable, repair or replace as needed. | 5/15/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. At least 3" of water is in pit. Sump pump should be inspected and repaired or replaced | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | The elevator machine rom cannot be used for storage. Remove the itelms being stored in the machine room to provide room for maintenance to be performed | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test is incomplete, relief test must be performed and door pressure measured. Re-inspection required |