Inspection
Inspection Details
Equipment ID
19189
19189
Inspection Date
4/2/2025
4/2/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
24
24
External ID
387cd8b5-6c51-43eb-8a06-2c1b4aa41750
387cd8b5-6c51-43eb-8a06-2c1b4aa41750
Location
Montclair on the Park
18 S Kingshighway Blvd, St. Louis, MO
Phone: (314) 560-2877
18 S Kingshighway Blvd, St. Louis, MO
Phone: (314) 560-2877
Owner
Attn: Montclair STL LLC
Montclair STL LLC
18 S Kingshighway Blvd, St. Louis, MO 63108
Phone: (000) 000-0000
Email: kbozoian@macapartments.com
Montclair STL LLC
18 S Kingshighway Blvd, St. Louis, MO 63108
Phone: (000) 000-0000
Email: kbozoian@macapartments.com
Billing
Attn: Montclair STL LLC
Montclair STL LLC
18 S Kingshighway Blvd, St. Louis, MO 63108
Phone: (000) 000-0000
Email: rwilk@sillimangroup.com
Montclair STL LLC
18 S Kingshighway Blvd, St. Louis, MO 63108
Phone: (000) 000-0000
Email: rwilk@sillimangroup.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc) | No | No | Suspension ropes shall have a rope data tag installed. | 5/1/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 8.11.2.1.2(d) | No | No | Remove all non-elevator related equipment from the machine room. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.11.2.1.2(e) (Re-Inspection) | No | No | Remove the excessive trash in the elevator machine room. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 4.8 - Hoistway enclosure | 8.11.2.1.4(h) | No | No | Provide lobby warning placards in all lobbies. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | No | No | Provide feeder location on main line and 110v disconnects. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 8.11.2.1.3(z) | No | No | Provide governor rope cable data tag. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | No | No | Provide a max counterweight runby sign in the pit. | 8/16/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.11 - Disconnecting Means and Control | 2.26.4 | No | No | Feeder locations shall be marked on main disconnects and car lighting branch circuit disconnects. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.4 - Machine space | 2.7.2.1 | No | No | Machinery and equipment not used in conjunction with the function or use of the elevator shall be removed from the elevator machine room. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | No | No | The penetrations in the hoistway overhead shall be sealed. | 9/24/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | A sign shall be posted adjacent to hall call fixtures instructing occupants not to use the elevator in case of fire. The sign shall include only the wording and graphics shown in Fig. 2.27.9 of A17.1-2005. | 9/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 5/14/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The emergency power fixture at the egress floor for this car shall be removed. This car does not operate under emergency power. | 5/14/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | The in car emergency lighting shall be operational. | 5/17/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency bell shall be operational. | 5/17/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | An up-to-date operating certificate is required in the machine room. | 5/18/2023 |