Inspection
Inspection Details
Equipment ID
10540
10540
Inspection Date
4/29/2025
4/29/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
Na
Na
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
25
25
External ID
cc0d7abf-992f-4111-97e1-14a85fe465d3
cc0d7abf-992f-4111-97e1-14a85fe465d3
Location
James House
4310 Saint Ferdinand Ave, St. Louis, MO
Phone: (314) 652-8997
Alt Phone: (314) 286-4221
Fax: (314) 286-4382
4310 Saint Ferdinand Ave, St. Louis, MO
Phone: (314) 652-8997
Alt Phone: (314) 286-4221
Fax: (314) 286-4382
Owner
Attn: James House
The Habitat Company
4310 Saint Ferdinand Ave, St. Louis, MO 63113
Phone: (314) 652-8997
Email: areeves@habitat.com
The Habitat Company
4310 Saint Ferdinand Ave, St. Louis, MO 63113
Phone: (314) 652-8997
Email: areeves@habitat.com
Billing
Attn: Andy Reeves
The Habitat Company
4451 Forest Park Ave, St. Louis, MO 63108
Phone: (618) 978-3338
Email: areeves@habitat.com
The Habitat Company
4451 Forest Park Ave, St. Louis, MO 63108
Phone: (618) 978-3338
Email: areeves@habitat.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Plunger for restricted opening missing replace | 2/13/2020 |
| conversion | conversion | conversion - reinspect | Yes | No | Phase II door open inoperative repair | 5/24/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Emergency light inoperative | 5/24/2019 |
| conversion | conversion | n/a | No | No | Clean pit | 2/13/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Reinspection of the emergency phone and it did not work. Reinspect when repaired | 9/23/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work, needs repair. Re-inspection required | 10/5/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | Car door restrictor does not work, needs repair. Re-inspection required | 10/5/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Replace damaged rollers on counterweight | 4/9/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Cotter pins are missing on counterweight tie rods. Repair | 4/9/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. Phone line problem | 4/9/2024 |
| A17.1-2016 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 8.6.4.11 Runby (Re-Inspect) | Yes | No | Counterweight runby is 0 inches. Shorten hoisting cables to provide 6 inches of counterweight runby. Re-inspection required | 6/27/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Yes | No | Need to clean debris from elevator pit. Re-inspection required | 6/27/2024 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Need to test elevator for operation on emergency power. Re-inspection required | 7/31/2025 |