Inspection
Inspection Details
Equipment ID
14251
14251
Inspection Date
4/22/2025
4/22/2025
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Phillip Moise, Jr.
Phillip Moise, Jr.
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
5ffceb41-6032-4f1c-8cf2-95a5c38c51d2
5ffceb41-6032-4f1c-8cf2-95a5c38c51d2
Location
Vangard Loft Apartments
1110 Washington Ave, St. Louis, MO
Phone: (314) 484-1543
Email: angie@opstl.com
1110 Washington Ave, St. Louis, MO
Phone: (314) 484-1543
Email: angie@opstl.com
Owner
Attn: Vangard Acquisitions, LLC
Vanguard Apartments LLC
1110 Washington Ave, St. Louis, MO 63101
Phone: (314) 350-6627
Email: vangard@opstl.com
Vanguard Apartments LLC
1110 Washington Ave, St. Louis, MO 63101
Phone: (314) 350-6627
Email: vangard@opstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | No | No | In the stairway leading up to the roof where the machine room is located there is a step that has a significant crack from end to end. Once on the roof there are also other steps that are damaged. These steps shall be repaired to provide safe and convenient access to the machine room. | 8/24/2023 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 8/24/2023 |
| A17.1-1996 : Elevators | 3.23 - Suspension rope | 1001.2(c)(29) | Yes | No | The counterweight buffer is compressed more than 25% before the elevator car reaches the final limit. The suspension ropes shall be shortened. Unit was locked out of service by maintenance company. | 9/12/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The hoistway switches were checked and fire service was tested. All other annual inspection items and category 5 testing items still remain and shall be tested to complete the inspection. | 9/12/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | There is no state operating certificate displayed in the machine room. | 10/10/2023 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | The fire extinguisher is expired. | 8/10/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key. The door does not lock. | 8/10/2024 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 8/10/2024 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit light shall be operational. | 8/10/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Firefighters phase one instructions shall be posted near the phase one key-switch in the hallway at the egress floor. | 8/10/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be guarded. | 8/10/2024 |
| A17.1-1996 : Elevators | 2.6 - Ventilation | 101.5b | No | No | The machine room temperature shall be kept within the manufacturers recommended range. The air conditioner is not working. | 8/10/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | No | No | The suspension ropes shall be tagged as specified CSR 40-5.065 (L)1 | 8/10/2024 |
| A17.1-1996 : Elevators | 1.13 - Emergency exit | 204.1e | Yes | No | The car-top emergency exit shall be secured to prevent it from falling down the hoistway. If a chain is used to secure it, it shall be not more than 12 inches in length and have a factor of safety of not less than 5. | 8/7/2024 |
| A17.1-1996 : Elevators | 1.13 - Emergency exit | 204.1e | Yes | No | The emergency exit cover shall be kept locked and only be openable from the top of the car, where it shall be openable without the use of special tools. | 8/7/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be guarded. | 8/7/2024 |
| A17.1-1996 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 201 | Yes | Yes | Standing water in pit. Water depth in pit is deep enough to submerge counterweight buffer switch. Elevator Red Tagged. | 4/22/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Yes | No | Sump pump is not working and shall be functional. | 4/22/2025 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way emergency communication device is not functioning and needs repair. | 4/22/2025 |
| A17.1-1996 : Elevators | 3.23 - Suspension rope | 206.7 | Yes | No | Retainers for suspension means shall be provided on deflecting and secondary sheaves. | 4/22/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Buffers, buffer switches, along with counterweight and runby must be checked to complete CAT 1 testing. | 4/22/2025 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way emergency communication device is not functioning and needs repair. | |
| A17.1-1996 : Elevators | 3.23 - Suspension rope | 206.7 | Yes | No | Retainers for suspension means shall be provided on deflecting and secondary sheaves. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Buffers, buffer switches, along with counterweight and runby must be checked to complete CAT 1 testing. | |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Yes | No | Sump pump is not working and shall be functional. |