Inspection
Inspection Details
Equipment ID
8743
8743
Inspection Date
5/16/2025
5/16/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dennis Smith
Dennis Smith
Mechanic Name
Dennis Smith Jr.
Dennis Smith Jr.
Relief Valve Pressure
N/A
N/A
Slide
4''
4''
Governor Rope Pull
N/A
N/A
Door Closing Force
>30
>30
External ID
f4535d0b-e9ba-4374-b085-2c6dfdae35f4
f4535d0b-e9ba-4374-b085-2c6dfdae35f4
Location
Village East Towers LTD
1218 Village Dr, St. Joseph, MO
Phone: (816) 364-5593
Email: Kevin.gray@conam.us
1218 Village Dr, St. Joseph, MO
Phone: (816) 364-5593
Email: Kevin.gray@conam.us
Owner
Attn: Maintenance Supervisor
Village East Towers LTD
1218 Village Dr, St. Joseph, MO 64506
Phone: (816) 364-5593
Fax: (816) 232-5323
Email: Kevin.gray@conam.us
Village East Towers LTD
1218 Village Dr, St. Joseph, MO 64506
Phone: (816) 364-5593
Fax: (816) 232-5323
Email: Kevin.gray@conam.us
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Install covers on 4x4 electrical gangboxes at top of hoistway | 2/22/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | No | No | Install suspension rope data tag to ropes | 2/22/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car door restrictor does not function. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | No | No | Install covers on conduit pullboxes located near top of hoistway. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.11.1 | No | No | Test and log firefighter operation monthly | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.9 - Guarding of exposed auxiliary equipment | 2.10.1 | No | No | Provide guarding of machine drive sheave and hoist ropes. | 11/19/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3.1 Capacity Plates | No | No | Install 2500 LBS Capacity plate inside the elevator. The existing capacity plate does not correspond with crosshead data plate. | 6/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.16 - Rated load, platform area, and data plate | 2.16.3.1 Capacity Plates | No | No | Install capacity plate inside the elevator "2000 lbs Capacity" | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | No | No | Machine room access door shall be self-closing | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 2.12.5 Restricted Opening of Hoistway or Car Doors (Re-Inspection) | Yes | No | Car door restrictor does not function | 5/16/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.7.2 Periodic Test Record (Test Tags) | No | No | Install and date period test tag | 11/13/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.8 - Door closing force | 2.13.4.2.3 | Yes | No | REDUCE DOOR TORQUE TO LESS THAN 30lbs | 10/10/2025 |