Inspection
Inspection Details
Equipment ID
25846
25846
Inspection Date
5/1/2025
5/1/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Donald Miles
Donald Miles
Relief Valve Pressure
530
530
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
24
24
External ID
596cd9fa-bea4-4673-a5ac-118e18057491
596cd9fa-bea4-4673-a5ac-118e18057491
Location
SafStor
2311 1st Capitol Dr, St. Charles, MO
Phone: (000) 000-0000
2311 1st Capitol Dr, St. Charles, MO
Phone: (000) 000-0000
Owner
Attn: SafStor Capitol, LLC
SafStor Capitol, LLC
2311 1st Capitol Dr, St. Charles, MO 63301
Phone: (000) 000-0000
Email: fac7703@extraspace.com
SafStor Capitol, LLC
2311 1st Capitol Dr, St. Charles, MO 63301
Phone: (000) 000-0000
Email: fac7703@extraspace.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | Yes | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 5/31/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.1.6(h) Audible/Visual Signal (Re-Inspection) | Yes | No | The fire service visual indicator in the hall shall work. | 5/31/2022 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.10.3.2.5(a) | Yes | No | The top bolts of the pit ladder are loose. | 5/31/2022 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Car Emergency System (Re-Inspection) | Yes | No | The in car emergency lighting shall be operational. | 5/31/2022 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.10.3.2.2(l) | Yes | No | An ABC type fire extinguisher is required to be located near the machine room door. | 5/31/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | All hall fixtures shall be properly installed and flush with the mounting surface. | 5/31/2022 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 8.7.2.1.1(b) | Yes | No | Seal the ceiling joint and edges at the top of the hoistway. | 5/31/2022 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 8.7.2.1.1(b) | Yes | No | Remove any wood and properly grout the hoistway door frames and all gaps and penetrations in the hoistway walls. | 5/31/2022 |
| A17.1-2016 : Elevators | 1.3 - Operating control devices | 8.10.3.2.1(c) | Yes | No | The main egress star on the COP and the numbers on the door jamb shall be at the 1st floor. | 5/31/2022 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 8.7.2.1.1(b) | Yes | No | Fire caulk all penetrations including, but not limited to, the sprinkler pipe, the sump discharge line and electrical conduit. | 5/31/2022 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.5 Sump Pump Required/Capacity (Re-Inspect) | Yes | No | Provide documentation of the sump pump capacity. | 5/31/2022 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/17/2025 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(d)(1) | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 5/17/2025 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | A record of findings for firefighters' service operation required by 8.6.11.1 with identification of the person(s) that performed the operation shall be available on-site. | 5/17/2025 |