Inspection
Inspection Details
Equipment ID
10215
10215
Inspection Date
12/12/2018
12/12/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
510
510
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
c441a3a7-86d2-4b69-841e-8bc0676fd001
c441a3a7-86d2-4b69-841e-8bc0676fd001
Location
Social Security Building
717 N 16TH ST, SAINT LOUIS, MO
717 N 16TH ST, SAINT LOUIS, MO
Owner
701 N,16th Street, LLC
10000 WATSON RD STE 1L5, SAINT LOUIS, MO 63126-1844
10000 WATSON RD STE 1L5, SAINT LOUIS, MO 63126-1844
Billing
Attn: 701 N, 16th Street, LLC
10000 WATSON RD STE 1L5, SAINT LOUIS, MO 63126-1844
10000 WATSON RD STE 1L5, SAINT LOUIS, MO 63126-1844
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency alarm bell does not work. | 6/25/2020 | |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | Emergency light does not work. | 6/25/2020 | |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | OSV test needs to be done on or before next inspection | 2/4/2023 | ||
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | A written MCP shall be in place to maintain the equipment in compliance with the state requirements | 2/4/2023 | ||
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | The cab ceiling is of the open egg-crate type, which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by plastic sleeve or some other means to properly protect passengers. | 8/8/2023 | ||
| A17.1-1996 : Elevators | 2.4 - Machine space | 101.1a | Ceiling tiles have been removed in the machine room, the ceiling tiles shall be reinstalled to maintain the fire resistance rating of the machine room. | 8/8/2023 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | x | This elevator has an overspeed valve device installed that is now required to have a 5 year full load test performed. This requirement is due to the State of Missouri adopting the A17.1 2016 version of the elevator safety code. Overspeed valve shall be tested within the next 30 days, this is the second notice. | 3/22/2023 | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The 5 year annual test has not been completed, the overspeed valve shall be tested. | 3/22/2023 | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | The cab ceiling is of the open egg crate type which does not provide protection from the light bulbs should they shatter. The lights shall be guarded by a plastic sleeve or some other means to properly protect passengers | 8/8/2023 | ||
| A17.1-1996 : Elevators | 2.4 - Machine space | 101.1a | Ceiling tiles have been removed in the machine room, the ceiling tiles shall be reinstalled to maintain the fire resistance rating of the machine room | 8/8/2023 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work. | 2/7/2024 |