Inspection
Inspection Details
Equipment ID
18587
18587
Inspection Date
5/20/2025
5/20/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Amador
Michael Amador
Mechanic Name
Zachary Thieme
Zachary Thieme
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
20
20
External ID
bed8a8e2-3c0a-4a6f-9bb0-711f8b5ce981
bed8a8e2-3c0a-4a6f-9bb0-711f8b5ce981
Location
Adler Frame Building
2035 Washington Ave, St. Louis, MO
Phone: (310) 363-0463
2035 Washington Ave, St. Louis, MO
Phone: (310) 363-0463
Owner
Attn: Adler Frame Building
Eagle Loft LLC
311 Belt Ave, St. Louis, MO 63112
Phone: (562) 201-3915
Email: zlovacinorev@gmail.com
Eagle Loft LLC
311 Belt Ave, St. Louis, MO 63112
Phone: (562) 201-3915
Email: zlovacinorev@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall work. | 2/12/2020 | |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide a code compliant MCP including onsite documents. | 3/29/2022 | ||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO state operating certificate shall be displayed in the elevator machine room. | 3/29/2022 | ||
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | x | The emergency brake release handle shall be operational. | 3/29/2022 | |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | A current tested ABC fire extinguisher shall be provided in the elevator machine room. | 3/29/2022 | ||
| A17.1-1996 : Elevators | 2.11 - Disconnecting Means and Control | 210.4 | The disconnect located in the machine space shall be provided with a sign to identify the location of the supply side overcurrent protective device. | 3/6/2026 | ||
| A17.1-1996 : Elevators | 2.27 - Rope fastenings | 212 | Wedge rope socket is anchored incorrectly. When the steel wire rope has been seated in the wedge socket by the load on the rope, the wedge shall be visible, and at least two wire-rope retaining clips shall be provided to attach the termination side to the load-carrying side of the rope. The first clip shall be placed a maximum of 4 times the rope diameter above the socket, and the second clip shall be located within 8 times the rope diameter above the first clip. | 3/6/2026 | ||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Clean the pit of oil, dirt, and debris. | 3/6/2026 | ||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | Fire extinguisher is expired. | 3/6/2026 | ||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | Up-to-date fire extinguisher is required in the machine room. | 3/6/2026 | ||
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Current operating certificate shall be posted in machine room | 3/6/2026 | ||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Pit shall be kept clean (oil from rail lubricators on pit floor) | 3/6/2026 | ||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Pit shall be kept clean | |||
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | Fire extinguisher in machine room shall be kept up to date. |