Inspection
Inspection Details
Equipment ID
26504
26504
Inspection Date
5/15/2025
5/15/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Amador
Michael Amador
Mechanic Name
Zachary Thieme
Zachary Thieme
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
20
20
External ID
1cfb3866-f0d6-49d4-8f93-7579ab4cd857
1cfb3866-f0d6-49d4-8f93-7579ab4cd857
Location
8400 Delmar
8400 Delmar Blvd, University City, MO
Phone: (000) 000-0000
Email: leasing@mckenzie-lux.com
8400 Delmar Blvd, University City, MO
Phone: (000) 000-0000
Email: leasing@mckenzie-lux.com
Owner
Attn: McKenzie-Anna Purna One LLC
McKenzie-Anna Purna One LLC
1 N Taylor Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: leasing@mckenzie-lux.com
McKenzie-Anna Purna One LLC
1 N Taylor Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: leasing@mckenzie-lux.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Elevators that are equipped to operate on emergency power shall be tested with no load in the car. | 5/8/2024 |
| A17.1-2016 : Elevators | 1.4 - Sills and car floor | 2.11.11.1 | Yes | No | 2.11.11.1(b) - Landing sills to be substantially flush with the floor surface of the elevator landings. | 5/8/2024 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | Yes | No | Top of hoistway:(2) 4 x 4 boxes are missing KO plugs. | 5/8/2024 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | Yes | No | Pit: (1) 4 x 4 box is missing KO plugs. | 5/8/2024 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | Yes | No | Pit: Lighting conduit needs to be secured. | 5/8/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.6 Sump Pump Covers | Yes | No | Pit sump pump cover is required. | 5/8/2024 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.4 | Yes | No | 2.2.4.2.4 - A clear distance of not less than 115 mm from the centerline of the rungs, cleats, or steps to the nearest permanent object in back of the ladder shall be provided. | 5/8/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Operating Certificate shall be posted in machine room. | 4/16/2025 |
| A17.1-2016 : Elevators | 3.14 - Hoistway clearances | 2.5 | No | No | Front door clutch shall have proper clearance to hoistway sill. Clutch is striking the hoistway sill on multiple floors. | 4/16/2025 |
| A17.1-2016 : Elevators | 6.5 -Acceptance Checklist for Firefighters' Service (ASME A17.1-2000 and CSA B44-00): Automatic Elevators | 2.27.1 | Yes | No | Phase 1 operating instruction shall be posted in hall. | 7/7/2025 |
| A17.1-2016 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Car Emergency System (Re-Inspection) | Yes | No | Emergency Light shall be operation and lens replaced (led board is bad) | |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.3.7 Phase 2 Operation Panel | Yes | No | Phase II, Rear door open and door close shall operate only with continuous pressure. | |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Machine roomless battery rescue operation (Schindler PEBO) shall be made operational. |