Inspection
Inspection Details
Equipment ID
6365
6365
Inspection Date
8/11/2025
8/11/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Wright
Michael Wright
Mechanic Name
Jerry Reasoner
Jerry Reasoner
Relief Valve Pressure
N/A
N/A
Slide
N/A
N/A
Governor Rope Pull
N/A
N/A
Door Closing Force
22
22
External ID
7b9a4465-6e42-483d-8137-b4a59b06097f
7b9a4465-6e42-483d-8137-b4a59b06097f
Location
Corby Building
422 Felix St, St. Joseph, MO
Phone: (816) 233-4600
Email: cburris@corbyplace.com
422 Felix St, St. Joseph, MO
Phone: (816) 233-4600
Email: cburris@corbyplace.com
Owner
Attn: Chris
Corby Senior Living
PO Box 374, Pico Rivera, CA 90660
Phone: (816) 752-4492
Email: cburris@corbyplace.com
Corby Senior Living
PO Box 374, Pico Rivera, CA 90660
Phone: (816) 752-4492
Email: cburris@corbyplace.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Need to post fire service instructions inside the elevator | 12/3/2019 | |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Need to replace governor rope due to excessive wire breaks and rouging. | 11/3/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | Need to post emergency evacuation of passengers form inside machine room. | 9/14/2020 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | Need to remove nonelevator related material and trash from machine room floor. | 9/14/2020 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.2 - Bottom clearance, runby, and minimum refuge space | 8.6.4.11 | x | Suspension ropes need to be shortened to provide proper runby. | 11/3/2020 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | Remount resistor on car controller. Resistor is hanging by electrical wires on resistor. | 7/16/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency bell does not operate | 7/16/2021 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Install seal on machine brake spring tension adjustment nut. | 7/16/2021 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | Remount resistor on controller. Resistor is hanging by electrical wires | 7/16/2021 | ||
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 12/8/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Replace worn traction sheave liners | 12/7/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.2.5 Rope Tension (Re-Inspect) | x | Equalize hoist rope tension | 12/8/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | Lobby dial position indicator does not operate and needs to be repaired. | 12/7/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | x | emergency lights not working. |