Inspection
Inspection Details
Equipment ID
23444
23444
Inspection Date
1/10/2019
1/10/2019
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Jeremiah Dugger
Jeremiah Dugger
Relief Valve Pressure
Slide
Stopped Level
Stopped Level
Governor Rope Pull
NA Na
NA Na
Door Closing Force
15
15
External ID
4a30b932-f303-49fa-b77d-0707e6da20d5
4a30b932-f303-49fa-b77d-0707e6da20d5
Location
Bear Village Phase 5
943 S KIMBROUGH AVE, SPRINGFIELD, MO
943 S KIMBROUGH AVE, SPRINGFIELD, MO
Owner
Bryan Hotels
840 S ROANOKE AVE, SPRINGFIELD, MO 65806-3491
840 S ROANOKE AVE, SPRINGFIELD, MO 65806-3491
Billing
Attn: Bryan Hotels
840 S ROANOKE AVE, SPRINGFIELD, MO 65806-3491
840 S ROANOKE AVE, SPRINGFIELD, MO 65806-3491
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 12/7/2020 |
| A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Room and Machinery Space | No | No | Unauthorized Material in machine room | 12/7/2020 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Maintenance records required | 12/7/2020 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post certificate | 2/1/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Required to be checked monthly | 2/1/2022 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 12/7/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | No records | 2/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No Records | 9/18/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 9/13/2023 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fireman's Recall system is to be checked monthly | 9/18/2024 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 8.6.4.8 Machine Room and Machinery Space | No | No | Unauthorize material | 9/18/2024 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated one | 9/18/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fireman's recall is to be checked monthly. | 9/18/2024 |