Inspection
Inspection Details
Equipment ID
7077
7077
Inspection Date
7/28/2025
7/28/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Raymond Stidham
Raymond Stidham
Mechanic Name
Sam Cones
Sam Cones
Relief Valve Pressure
450
450
Slide
Governor Rope Pull
Door Closing Force
18
18
External ID
52266dbe-d051-4608-bdbd-90ded13ceb64
52266dbe-d051-4608-bdbd-90ded13ceb64
Location
Seasons III, Phase II
1545 E ERIE ST, SPRINGFIELD, MO
Phone: (417) 881-3216
1545 E ERIE ST, SPRINGFIELD, MO
Phone: (417) 881-3216
Owner
Attn: Candy Applegate
The Wooten Co LLC
1675 E Seminole St, Springfield, MO 65804
Phone: (417) 883-8365
Email: candy@thewootenco.com
The Wooten Co LLC
1675 E Seminole St, Springfield, MO 65804
Phone: (417) 883-8365
Email: candy@thewootenco.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | needs fire extinguisher in machine room | 7/28/2020 |
| conversion | conversion | n/a | No | No | Jack needs to be repacked | 7/28/2020 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)4 | No | No | 8.6.12.3.7.2 Packing gland needs replaced | 7/28/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | clean all oil and debree from pit | 7/28/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | 1.6 telephone will not call out | 6/2/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | 8.6.12.3.7.2 and 8.6.5.5.1 jack needs to be repacked | 7/28/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | pit needs to be clean of oil and debree | 7/28/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | ceiling panel missing--needs bulb protection | 7/28/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | jack packing needs replaced | 7/28/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | no current certificate on site | 7/28/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean Pit | 2/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Jack seal required replacement | 2/22/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Must Post current State Cert. in Machine room. 5.100(2) | 2/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Must provide current annual test tag on Mach. room Fire Extinguisher. 8.6.1.6.5 | 2/22/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Must make right car door reopening devise operable. 8.6.4.13 | 6/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Main operating valve needs to be replaced. | 9/12/2025 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water in pit | 9/12/2025 |