Inspection
Inspection Details
Equipment ID
22449
22449
Inspection Date
8/14/2025
8/14/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Amador
Michael Amador
Mechanic Name
Nathaniel Smith
Nathaniel Smith
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
959f0fb8-becd-42f6-9d9a-9db97f61c962
959f0fb8-becd-42f6-9d9a-9db97f61c962
Location
IKEA Property
1 Ikea Way, St. Louis, MO
Phone: (314) 721-0410
1 Ikea Way, St. Louis, MO
Phone: (314) 721-0410
Owner
Attn: IKEA Property
IKEA Property
1 Ikea Way, St. Louis, MO 63110
Phone: (000) 000-0000
Email: dl.site.area.prep.410.us@ingka.com
IKEA Property
1 Ikea Way, St. Louis, MO 63110
Phone: (000) 000-0000
Email: dl.site.area.prep.410.us@ingka.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 6.1.3.3.5 | No | No | Step indexing could not be completed due to out of calibration equipment. Reinspection Required. | 11/26/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Clean escalator pit. | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | Yes | No | Upper demarcation lights not working | 12/17/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 6.1.3.3.9 Step/Skirt Performance Index | Yes | No | Unit failed indexing,repair as needed. | 12/17/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.19 - Maintenance records | 8.6.1.4 | No | No | Provide MCP | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.7 - Combplate and comb step impact device | 6.1.6.3.13 | Yes | No | Comb plate impact switches could not be tested due to comb plate screws being stripped out, repair and perform comb plate impact switch tests. Re-inspection required | 5/23/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | Need to clean dirt & debris from escalator pits | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.1.6.3 | No | No | Provide electrical prints for escalator | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | Yes | No | Repair step demarcation lights at both landings. Re-inspection required | 8/14/2025 |
| A17.1-2016 : Elevators | 7.5 - Lighting | 6.1.7.2 | No | No | Demarcation Light not working at top or bottom. | 1/23/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | Yes | No | Escalator truss shall get a clean down |