Inspection
Inspection Details
Equipment ID
13497
13497
Inspection Date
8/18/2025
8/18/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Brant Willtrout
Brant Willtrout
Relief Valve Pressure
570
570
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
22F/25R
22F/25R
External ID
f509d55f-1aa9-48f2-8763-7c8d2b81ac03
f509d55f-1aa9-48f2-8763-7c8d2b81ac03
Location
Webster Groves Animal Hospital
8028 BIG BEND BLVD, WEBSTER GROVES, MO
Phone: (314) 255-6280
8028 BIG BEND BLVD, WEBSTER GROVES, MO
Phone: (314) 255-6280
Owner
Attn: Webster Groves Animal Hospital
Webster Groves Animal Hospital
8028 Big Bend Blvd, Webster Groves, MO 63119
Phone: (314) 255-6280
Email: rbeaulieu@webstervets.com
Webster Groves Animal Hospital
8028 Big Bend Blvd, Webster Groves, MO 63119
Phone: (314) 255-6280
Email: rbeaulieu@webstervets.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.32 - Control Valve | 1004.2(b)(15) | No | No | Car failed 15 minute standing test and appears that the oil is leaking back through the control valve. Diagnose and repair or replace as required. | 10/21/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | The car top and hoistway shall be cleaned. | 12/1/2022 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit shall be kept clean. Clean the pit. | 12/1/2022 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 12/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | The pit and hoistway need to be cleaned. There is an excessive amount of animal hair in the hoistway and pit. | 12/1/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | The top of the car shall be cleaned off. | 12/1/2022 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve in 2021 or 2022. The valve shall be sealed and tagged after the category 5 test. | 12/7/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. | 6/8/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | There is no state operating certificate in the machine room. | 8/2/2023 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | No | No | The pit floor needs to be cleaned. | 8/2/2023 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | No | No | The pit needs a new light bulb. | 8/2/2023 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | The hoistway needs to be cleaned. | 8/2/2023 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. | 11/22/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | When phase I is keyed on, the elevator comes down and rear entrance doors open. Doors have to open in front where key is located. |