Inspection
Inspection Details
Equipment ID
16740
16740
Inspection Date
8/21/2025
8/21/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
26F/25R
26F/25R
External ID
d2c1e1e4-f3b7-4854-8082-ee72ca7f3144
d2c1e1e4-f3b7-4854-8082-ee72ca7f3144
Location
Webster Groves Masonic Lodge
12 E Lockwood Ave, Webster Groves, MO
Phone: (314) 374-1527
12 E Lockwood Ave, Webster Groves, MO
Phone: (314) 374-1527
Owner
Attn: Webster Groves Masonic Lodge
Webster Groves Masonic Lodge
12 E Lockwood Ave, Webster Groves, MO 63119
Phone: (000) 000-0000
Email: WebsterGrovesMTA@gmail.com
Webster Groves Masonic Lodge
12 E Lockwood Ave, Webster Groves, MO 63119
Phone: (000) 000-0000
Email: WebsterGrovesMTA@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Outside door at the top of the hoistway needs to be locked at all times. The lock is not operating properly. | 7/6/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | The outside door at the top of the hoistway shall have signage installed that states: " Danger, Open Elevator Hoistway". | 7/6/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Patch the holes in the hoistway. | 3/26/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be displayed in the elevator machine room. | 3/26/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 3/26/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 6/15/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) | No | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 6/15/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 6/15/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Install a code data plate. It shall read: Missouri Minimums. | 6/15/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | All machine rooms or enclosures shall have a self-locking and self-closing door and shall be operable from the interior space without the use of a key. | 6/15/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)15 | No | No | Outside door at the top of the hoistway needs to be locked at all times, it shall have a self-locking door and shall be operable from the interior space without the use of a key. The outside of the door shall have signage that shall be installed that states: "Danger, Open Elevator Hoistway". | 6/15/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 11/17/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | Yes | Counterweight buffer spring compromised by water/rust damage. Fell over. Reinspection required to return to service. Elevator Red Tagged. | 4/15/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Yes | No | Pit channel (car side) compromised by water/rust damage. Replace channel. | 4/15/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)1(A) | No | No | Hoist ropes appear dry and showing "rouge". Ropes shall be cleaned and lubricated per OEM recommendations. | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit shall be kept clean and dry. Remove rust from pit equipment, repair/replace as needed, apply rust prevention treatment to all pit steel, investigate/repair water leak. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. |