Inspection
Inspection Details
Equipment ID
15442
15442
Inspection Date
10/1/2025
10/1/2025
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Michael Amador
Michael Amador
Mechanic Name
Richard Babor III
Richard Babor III
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
150
150
Door Closing Force
24
24
External ID
9c816e03-68fc-458a-b504-2dc7e2e8b4b4
9c816e03-68fc-458a-b504-2dc7e2e8b4b4
Location
Euclid + Pine
4907 W Pine Blvd, St. Louis, MO
Phone: (636) 231-5726
4907 W Pine Blvd, St. Louis, MO
Phone: (636) 231-5726
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Install proper emergency exit cover. Must be designed to support weight and secured so that it can only be opened from the car top without the use of tools. | 12/12/2018 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)1 | Yes | Yes | Test the car safeties and provides means (tool) to wind up safeties for testing. | 2/19/2020 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)9 Capacity Plate | No | No | Provide means for substantially level floor. Pull out hole creates a tripping hazard. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-locking and self-closing. | 9/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Provide a current tested fire extinguisher in the machine room. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Wooden stairway treads to access machine and controller are worn and damaged and shall be replaced or repaired as needed. | 9/15/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display current state operating certificate. | 9/15/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Emergency exit is not code compliant. | 9/15/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit light shall work. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide code compliant lighting in the machine room (10 FTC minimum). | 9/15/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The governor rope pullout shall be 42" or less. | 9/7/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The debris in the pit shall be removed. The pit shall be kept clean. | 9/15/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit lighting shall be operational. | 9/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | The car safety key shall be kept on-site. | 9/15/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | The emergency exit shall be capable of sustaining a load of 300 lbs. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all material from the machine room which is not required for the operation of maintenance of the elevator. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | The wooden steps going up to the machine room deck are damaged and shall be replaced. | 9/15/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | The exposed wiring on the car top and in the hoistway at the 2nd landing shall be enclosed. | 9/15/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | All wireway and electrical device covers must be installed. | 9/15/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide a current tested ABC fire extinguisher in the machine room. | 9/15/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide a minimum of 10 ft candles of illumination measured at the floor through out the machine room | 9/27/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Remove exposed wiring and splices from car top and replace with proper NEC wiring | 9/27/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide MCP. | 6/1/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 6/1/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Provide existing pit light to work. | 6/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Provide safe and convenient access to the elevator machine room, wooden steps leading in are damaged. | 6/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | First plank into the machine room needs to be secured down. Trip hazard. | 6/1/2024 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self locking / self closing | 7/1/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Electrical wiring provided for new cab lighting shall be protected & open splices enclosed in junction boxes per NFPA 70 | 7/1/2024 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Provide a current tested ABC fire extinguisher in the machine room. | |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Exposed wiring and splices on cartop need to be enclosed per NEC. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Car would not pick load. Safeties were not set. Need to return when repairs have been made to set safeties to complete 5 year test. |