Inspection
Inspection Details
Equipment ID
21023
21023
Inspection Date
9/29/2025
9/29/2025
Inspection Type
Reinspection
Reinspection
Inspector Name
Thomas Krug
Thomas Krug
Mechanic Name
Relief Valve Pressure
na
na
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
95f20427-1d99-4300-b4f6-5b69cdf49978
95f20427-1d99-4300-b4f6-5b69cdf49978
Location
Salvation Army Veterans Housing
2935 Locust St, St. Louis, MO
Phone: (314) 652-3310
2935 Locust St, St. Louis, MO
Phone: (314) 652-3310
Owner
Attn: Laurie Betts
Salvation Army Veterans Housing
2935 Locust St, St. Louis, MO 63103
Phone: (314) 441-0475
Email: garrison3010@alexandercompany.com
Salvation Army Veterans Housing
2935 Locust St, St. Louis, MO 63103
Phone: (314) 441-0475
Email: garrison3010@alexandercompany.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | AMaintenanceControlProgramforeachunit(see 8.6.1.1.1) shall be provided by the person(s) and/or firm maintaining the equipment and shall be viewable on- site by elevator personnel at all times from time of acceptance inspection and test or from the time of equip- ment installation or alteration | 8/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.27 - Crosshead data plate | 8.11.2.1.3(k) | No | No | Need crosshead data plate | 8/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | Safety Retainers missing from bottom of Hoistway doors.The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail, | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6 | 8/1/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.17 - Door and gate equipment | 8.11.2.1.3(w) | No | No | 2.11.11.8 Bottom safety retainers missing from hoistway doors. The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail. | 8/1/2023 |
| A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.6.3.2 (Re-Inspection) | Yes | No | Hoist Ropes showing excessive rouge have stretched reducing diameter beyond maximum allowable amount. Replace hoist ropes. | 9/21/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Provide Crosshead Data Tag | 8/1/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Bottom safety retainers missing from hoistway doors. The top and bottom of horizontally sliding doors shall be provided with a means of retaining the closed door panel in position if the primary guiding means fail. | 1/17/2024 |
| A17.1-2016 : Elevators | 3.27 - Crosshead Data Plate and Rope Data Tags | 8.11.2.1.3(k) | No | No | Provide Crosshead Data Plate compliant with section 2.16.3 | 1/17/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The Emergency Phone in the car fails to establish two-way communication. | 10/8/2025 |