Inspection
Inspection Details
Equipment ID
9183
9183
Inspection Date
9/29/2025
9/29/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Nathaniel Smith
Nathaniel Smith
Relief Valve Pressure
NA
NA
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
NA
NA
External ID
4af03e07-5f91-41a5-aa53-320919ff1d2e
4af03e07-5f91-41a5-aa53-320919ff1d2e
Location
Macy's- West Store / #652
2 W County Ctr # 120012, St. Louis, MO
Phone: (314) 966-0017
2 W County Ctr # 120012, St. Louis, MO
Phone: (314) 966-0017
Owner
Attn: TSG PROPERTIES
TSG PROPERTIES
237 Woodbridge Center Dr, 3rd Flr, Woodbridge, NJ 07095
Phone: (314) 471-4975
TSG PROPERTIES
237 Woodbridge Center Dr, 3rd Flr, Woodbridge, NJ 07095
Phone: (314) 471-4975
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Replace missing section of Balustrade trim | 6/15/2020 |
| conversion | conversion | n/a | No | No | Replace steps with chipped edges | 6/15/2020 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Repari skirt lights (bottom) | 6/15/2020 |
| A17.1-1996 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 806 | No | No | Clean lower upper pits | 6/15/2020 |
| A17.1-1996 : Escalators | 8.5 - Speed governor | 805.3b | Yes | Yes | Repair break Red Tagged | 10/29/2019 |
| A17.1-1996 : Escalators | 7.15 - Balustrades | 802.3 | No | No | Replace missign Balustrade trim section | 6/15/2020 |
| A17.1-1996 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 802.3e | No | No | Provide copy of step indexing test results to complete inspection | 6/15/2020 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 10/9/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.6 Steps | Yes | No | Replace broken step treads | 4/13/2022 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean down truss | 10/9/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | Yes | No | Adjust skirts & perform step skirt indexing within 30 days | 4/13/2022 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 10/9/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean down truss | 10/9/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.6 Steps | Yes | No | Replace broken step tread | 10/9/2025 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 806.3 | No | No | CLEAN DOWN TRUSS | 11/18/2025 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | repair skirt entrance lights top and bottom | 11/18/2025 |
| A17.1-1996 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | POST CURRENT STATE CERTIFICAE IN THE MACHINE ROOM | 11/18/2025 |
| A17.1-1996 : Escalators | 7.3 - Handrails | 802.2 | No | No | REPLACE BOTH HANDRAILS | 11/18/2025 |
| A17.1-1996 : Escalators | 7.7 - Combplate and comb step impact device | 805.3n | No | No | REPAIR COMB IMPACT SWITCHES TOP & BOTTOM | 11/18/2025 |
| A17.1-1996 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 802.3e | Yes | No | Complete Skirt Index test | 11/18/2025 |
| A17.1-1996 : Escalators | 8.12 - Steps, step chains, and trusses | 801.1 | No | No | Clean Trusses Down | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Repair Skirt Entrance Lights | |
| A17.1-1996 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | Post Current State Certificate |