Inspection
Inspection Details
Equipment ID
16741
16741
Inspection Date
10/3/2025
10/3/2025
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Cynthia "CJ" Brady
Cynthia "CJ" Brady
Mechanic Name
Tom Worsham
Tom Worsham
Relief Valve Pressure
500
500
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
24
24
External ID
f7ffbbf6-ed04-4375-8cd8-976e54b54e1a
f7ffbbf6-ed04-4375-8cd8-976e54b54e1a
Location
CVS Pharmacy
8101 Clayton Rd, Clayton, MO
Phone: (636) 220-6850
8101 Clayton Rd, Clayton, MO
Phone: (636) 220-6850
Owner
Attn: CVS Pharmacy
CVS Pharmacy
8101 Clayton Rd, Clayton, MO 63117
Phone: (847) 372-2454
Email: service@a-prime.com
CVS Pharmacy
8101 Clayton Rd, Clayton, MO 63117
Phone: (847) 372-2454
Email: service@a-prime.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Phase 1 fire service key switch is broken and shall be repaired. All fire service features shall be tested. | 2/13/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell shall work. | 2/13/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Emergency light shall work. | 1/27/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | Yes | No | Existing car door restrictor does not work and shall be repaired and tested. | 2/13/2019 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | Yes | During Phase 2 fire service, the elevator will not go back to normal operation and is stuck on fire service. Elevator Red Tagged. | 5/24/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | There is no MCP present. | 8/28/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A current ABC type fire extinguisher shall be provided in the machine room. | 8/28/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | Second floor spring closer is missing on hoist door. | 11/26/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 9/1/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept clean. | 9/1/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2 On-Site Documentation | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 9/1/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Holes in hoistway at the 2nd floor shall be repaired. | 9/1/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | CAR DOOR SHALL BE RESTRICTED FROM OPENING (more than 4") WHEN OUTSIDE DOOR ZONE | |
| MO Minimum : Elevators | (S) - Fire Service | 211.8 Switch Keys | Yes | No | When the car is at a landing other than the recall level, with the doors in the normal open position, and, the Phase 2 switch is returned to the ”OFF” position, the car shall recall to the main landing. Currently, went returned to "OFF", the car performs as it it was still "ON". | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lighting - All lamps shall work and be guarded from breakage. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Car door to return jamb gaps are greater than Code max of 0.5". | |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Holes in hoistway at the 2nd floor shall be repaired. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Replace missing/damaged pickup roller(s) @ floor 1. |